IEEE Transactions on Instrumentation and Measurement · 2020 · 21 citations · 20 references
MedicineBiomedical EngineeringCardiologyBiomedical ImagingDiagnostic ImagingUltrasonographyCardiac ImagingCardiovascular ImagingCoronary Artery ImagingIntravascular ImagingMedical Image AnalysisMedical ImagingAutomated Plaque DetectionCoronary Artery Disease ImagingCoronary Lesion AssessmentCoronary Vessel Wall ImagingCross-sectional ImagingHigh-resolution Coronary ImagingNoise Parameter ExtractionParameter Extraction
Intravascular ultrasound (IVUS) can provide high-resolution cross-sectional images of coronary arteries, showing detailed information of the vascular lumen, tube wall, and athermanous plaques, which is helpful for the discovery or identification of early coronary atherosclerotic plaques. Multiple parameters extractable from the IVUS image can help the cardiologist analyze the pathology and assist in disease diagnosis and postoperative treatment. Typically, cardiologists manually label the intima and adventitia in the IVUS image, and obtain a limited number of parameters through the IVUS instrument, which is time consuming and labor-intensive. To assist the cardiologist in automatically obtaining more clinically relevant value parameters, a fully automatic IVUS multiparameter extraction framework is proposed. Based on the intima and adventitia obtained by DeepLab V3+, we propose a targeted noise reduction preprocessing framework adapted to IVUS. The framework implements the basic parameter extraction of IVUS through two newly proposed algorithms. And through the standard medical formula, the basic parameters are converted into 10 standard medical indicators. Standardized medical indicators are obtained by clinically relevant basic parameters. In terms of accuracy, this article used a clinical database obtained from Qilu Hospital of Shandong University and compared the results of the framework with the gold standard of cardiologists. The relative error of continuous IVUS main parameters between frames did not exceed 10.10%. The relative error of independent IVUS did not exceed 10.03%. Based on the distribution consistency of the parameters and the gold standard, a Bland-Altman plot of the parameters is proposed. It was verified that this distribution is basically in line with the gold standard of cardiologists. The algorithm in this article obtained a total of 10 parameters, far exceeding the parameters obtained by cardiologists and traditional IVUS machines. Its accuracy and speed can also meet the requirements of cardiologists for clinical diagnosis.
20
Deep Residual Learning for Image Recognition
Kaiming He, Xiangyu Zhang, Shaoqing Ren et al. · 2016 · 222.1K citations · Full text
Fully convolutional networks for semantic segmentation
Jonathan Long, Evan Shelhamer, Trevor Darrell · 2015 · 36.9K citations
Hengshuang Zhao, Jianping Shi, Xiaojuan Qi et al. · 2017 · 15.5K citations
Conditional Random Fields as Recurrent Neural Networks
Shuai Zheng, Sadeep Jayasumana, Bernardino Romera‐Paredes et al. · 2015 · 2.4K citations · Full text
Recurrent Neural Network Regularization
Wojciech Zaremba, Ilya Sutskever, Oriol Vinyals · arXiv (Cornell University) · 2014 · 2.3K citations · Full text