Review of noise removal techniques in ECG signals

Shubhojeet Chatterjee, Rini Smita Thakur, Ram Narayan Yadav, Lalita Gupta, D. K. Raghuvanshi

IET Signal Processing · 2020 · 317 citations · 133 references

Concepts

TL;DR

An electrocardiogram records the heart’s electrical activity but is vulnerable to noise, making denoising a crucial pre‑processing step that enhances characteristic waves and has led researchers to propose numerous morphological anomaly detection methods. This study outlines the workflow and design principles of existing denoising techniques, classifying them into categories for comparison and guiding the development of modern ECG denoising methods. The authors evaluate these techniques on benchmark metrics—root‑mean‑square error, percentage‑root‑mean‑square difference, and signal‑to‑noise ratio improvement—across MIT‑BIH, PTB, QT, and other databases. Wavelet‑VBE, EMD‑MAF, GAN2, GSSSA, new MP‑EKF, DLSR, and AKF excel at additive white Gaussian noise removal; GAN1, new MP‑EKF, DLSR, and AKF perform well on muscle artefacts; GAN1 is best for baseline wander and electrode motion; DLSR and EWT handle power‑line interference; and FCN‑based DAE, DWT (Sym6) soft, MABWT (soft), CPSD sparsity, and UWT show promise for composite noise removal.

Abstract

An electrocardiogram (ECG) records the electrical signal from the heart to check for different heart conditions, but it is susceptible to noises. ECG signal denoising is a major pre-processing step which attenuates the noises and accentuates the typical waves in ECG signals. Researchers over time have proposed numerous methods to correctly detect morphological anomalies. This study discusses the workflow, and design principles followed by these methods, and classify the state-of-the-art methods into different categories for mutual comparison, and development of modern methods to denoise ECG. The performance of these methods is analysed on some benchmark metrics, viz., root-mean-square error, percentage-root-mean-square difference, and signal-to-noise ratio improvement, thus comparing various ECG denoising techniques on MIT-BIH databases, PTB, QT, and other databases. It is observed that Wavelet-VBE, EMD-MAF, GAN2, GSSSA, new MP-EKF, DLSR, and AKF are most suitable for additive white Gaussian noise removal. For muscle artefacts removal, GAN1, new MP-EKF, DLSR, and AKF perform comparatively well. For base-line wander, and electrode motion artefacts removal, GAN1 is the best denoising option. For power-line interference removal, DLSR and EWT perform well. Finally, FCN-based DAE, DWT (Sym6) soft, MABWT (soft), CPSD sparsity, and UWT are promising ECG denoising methods for composite noise removal.

References

133