European Urology · 2020 · 90 citations · 23 references
MedicineOncologySurgeryMedical RoboticsOncologic SurgerySurgical OncologyProstate SurgeryRobot-assisted SurgeryRobotic Urologic SurgerySentinel Lymph Node ImagingSentinel Lymph Node MappingSurgical RoboticsExtended Pelvic Lymph Node DissectionIndocyanine Green ImagingIntraoperative Gamma Probe GuidanceIntraoperative Image GuidanceIntraoperative Sentinel Node DetectionPreoperative Imaging GuidanceRobot-assisted Radical ProstatectomySentinel Node Radioguided Surgery
BACKGROUND: The DROP-IN gamma probe was introduced to overcome the restricted manoeuvrability of traditional laparoscopic gamma probes. Through enhanced manoeuvrability and surgical autonomy, the DROP-IN promotes the implementation of radioguided surgery in the robotic setting. OBJECTIVE: To confirm the utility and safety profile of the DROP-IN gamma probe and to perform a comparison with the traditional laparoscopic gamma probe and fluorescence guidance. DESIGN, SETTING, AND PARTICIPANTS: Twenty-five prostate cancer patients were scheduled for a robot-assisted sentinel lymph node (SN) procedure, extended pelvic lymph node dissection, and prostatectomy at a single European centre. SURGICAL PROCEDURE: Tc-nanocolloid + ICG (n = 13), SN locations were defined using preoperative imaging. Surgical excision of SNs was performed under image guidance using the DROP-IN gamma probe, the traditional laparoscopic gamma probe, and fluorescence imaging. MEASUREMENTS: Intraoperative SN detection was assessed for the different modalities and related to anatomical locations. Patient follow-up was included (a median of 18 mo). RESULTS AND LIMITATIONS: Overall, 47 SNs were pursued in vivo by the DROP-IN gamma probe, of which 100% were identified. No adverse events related to its use were observed. In vivo fluorescence imaging identified 91% of these SNs. The laparoscopic gamma probe identified only 76% of these SNs, where the detection inaccuracies appeared to be related to specific anatomical regions. CONCLUSIONS: Owing to improved manoeuvrability, the DROP-IN probe yielded improved SN detection rates compared with the traditional gamma probe and fluorescence imaging. These findings underline that the DROP-IN technology provides a valuable tool for radioguided surgery in the robotic setting. PATIENT SUMMARY: Radioguided robot-assisted surgery with the novel DROP-IN gamma probe is feasible and safe. It enables more efficient intraoperative identification of sentinel lymph nodes than can be achieved with a traditional laparoscopic gamma probe. The use of the DROP-IN probe in combination with fluorescence imaging allows for a complementary optical confirmation of node localisations.
23
Axel Heidenreich, Joaquim Bellmunt, M. Bolla et al. · 2013 · 864 citations
Alberto Briganti, Alessandro Larcher, Firas Abdollah et al. · European Urology · 2011 · 787 citations
Mapping of Pelvic Lymph Node Metastases in Prostate Cancer
Steven Joniau, Laura Van den Bergh, Evelyne Lerut et al. · European Urology · 2012 · 269 citations