IEEE Transactions on Nuclear Science · 2020 · 77 citations · 35 references
EngineeringElectrical EngineeringMaterials ScienceElectronic MaterialsNuclear PhysicsSemiconductor DevicesRadiation Damage In MaterialsRadiation DetectorsRadiation HardeningSemiconductor DetectorsSemiconductor Device MaterialsSemiconductor ReliabilityIrradiation EffectsP-n Junction DetectorsRadiation EffectsRadiation HardnessRadiation MonitoringSemiconductor Radiation DetectorsSilicon CarbideSilicon Carbide (Sic) Materials
Owing to their low dark current, high transparency, high thermal conductivity, and potential radiation hardness, there is a special interest in silicon carbide (SiC) devices for radiation monitoring in radiation harsh environments and with elevated temperatures and, especially, for the plasma diagnostic systems in future nuclear fusion reactors. In this work, four-quadrant p-n junction diodes produced on epitaxial 4H-SiC substrates are studied. The impact of electron, neutron, and proton irradiations (up to fluences of 1 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">16</sup> electrons (e)/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> , 2 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">15</sup> neutrons (n)/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> , and 2.5 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">15</sup> protons (p)/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> , respectively) on the electrical characteristics is studied by means of current-voltage (I-V) and capacitance-voltage (C-V) techniques. Regardless of the particle type and applied fluences, the results show similar low reverse currents for irradiated SiC devices, which are at least about four orders of magnitude lower than comparable Si devices. The effects of irradiation on interquadrant resistance and charge build-up in the interquadrant isolation are assessed. Furthermore, device performance as a radiation detector is investigated upon exposure to a collimated <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">239</sup> Pu- <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">241</sup> Am- <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">244</sup> Cm trialpha source. The performance at room temperature is preserved even for the highest irradiation fluences, despite the fact that the rectification character in electrical characteristics is lost. From the results, advantages of using SiC devices in alpha particle detection in harsh environments can be envisaged.
35
Silicon carbide and its use as a radiation detector material
F. Nava, G. Bertuccio, A. Cavallini et al. · Measurement Science and Technology · 2008 · 495 citations · Full text
SiCILIA—Silicon Carbide Detectors for Intense Luminosity Investigations and Applications
S. Tudisco, Francesco La Via, C. Agodi et al. · Sensors · 2018 · 266 citations · Full text