Publication | Closed Access
Neuromuscular Blockade Monitoring in Acute Respiratory Distress Syndrome: Randomized Controlled Trial of Clinical Assessment Alone or With Peripheral Nerve Stimulation
20
Citations
19
References
2020
Year
In patients with ARDS, adding TOF to clinical monitoring of neuromuscular blockade did not change ICU mortality or days on mechanical ventilation (MV) but did increase atracurium consumption when compared to clinical assessment alone. TOF monitoring may not be needed in all patients who receive neuromuscular blockade for ARDS.