Applied Sciences · 2020 · 14 citations · 15 references
EngineeringElectrical EngineeringElectromagnetismMetallic MaterialsPower ElectronicsElectric CircuitsElectrical SafetyElectrical TechnologyElectrical WiringTransmission LinesBondingCable DistributionCable SystemsCurrentsHigh-voltage Power SystemsHigh-voltage Transmission LinesShort-circuit CurrentShort-circuit Power
Load currents and short-circuit currents in high-voltage power cable lines are sources of the induced voltages in the power cables’ concentric metallic sheaths. When power cables operate with single-point bonding, which is the simplest bonding arrangement, these induced voltages may introduce an electric shock hazard or may lead to damage of the cables’ outer non-metallic sheaths at the unearthed end of the power cable line. To avoid these aforementioned hazards, both-ends bonding of metallic sheaths is implemented but, unfortunately, it leads to increased power losses in the power cable line, due to the currents circulating through the sheaths. A remedy for the circulating currents is cross bonding—the most advanced bonding solution. Each solution has advantages and disadvantages. In practice, the decision referred to its selection should be preceded by a wide analysis. This paper presents a case study of the induced sheath voltages in a specific 110 kV power cable line. This power cable line is a specific one, due to the relatively low level of transferred power, much lower than the one resulting from the current-carrying capacity of the cables. In such a line, the induced voltages in normal operating conditions are on a very low level. Thus, no electric shock hazard exists and for this reason, the simplest arrangement—single-point bonding—was initially recommended at the project stage. However, a more advanced computer-based investigation has shown that in the case of the short-circuit conditions, induced voltages for this arrangement are at an unacceptably high level and risk of the outer non-metallic sheaths damage occurs. Moreover, the induced voltages during short circuits are unacceptable in some sections of the cable line even for both-ends bonding and cross bonding. The computer simulations enable to propose a simple practical solution for limiting these voltages. Recommended configurations of this power cable line—from the point of view of the induced sheath voltages and power losses—are indicated.
15
Mingzhen Li, Chengke Zhou, Wenjun Zhou · IEEE Transactions on Power Delivery · 2019 · 33 citations · Full text
The calculation of circulating current for the single-core cables in Smart Grid
Zhonglei Li, Boxue Du, Li Wang et al. · 2012 · 31 citations