EJNMMI Physics · 2020 · 35 citations · 16 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDiagnostic Imaging SystemsImage ReconstructionImagingMedical ImagingMedical Imaging InstrumentationPositron Emission TomographyBackground Noise MeasurementData Acquisition ParametersDetector Timing ResolutionImage Acquisition ParametersPet Image ReconstructionPet-computed TomographyReconstruction AlgorithmsTiming Resolution
BACKGROUND: The purpose of this work was to propose an approach based on noise measurement to adapt present clinical acquisition and reconstruction parameters adapted to a PMT-based system (Biograph mCT) to a SiPM-based system (Biograph Vision 450) sharing identical geometrical properties. The NEMA performance (NEMA) of the recently released Biograph Vision 450 PET/CT (Vision) was also derived. METHODS: All measurements were conducted on Vision and Biograph mCT with TrueV (mCT). A full NEMA-based performance was derived for Vision only. The adaptation of acquisition and reconstruction parameters from mCT to Vision was done using the NEMA image quality phantom. The noise level reached using mCT was set as the reference value for six different numbers of net true coincidences. The noise level computed using Vision was matched to the reference noise level (within 0.01%) using a different reconstruction set-up to determine the potential reduction of count numbers for the same noise level. RESULTS: Vision sensitivity was 9.1 kcps/MBq for a timing resolution of 213 ps at 5.3 kBq/mL. The NEMA-based CR for the 10-mm sphere was better than 75% regardless the reconstruction set-up studied. The mCT reference noise properties could be achieved using Vision with a scan time reduction (STR) of 1.34 with four iterations and a 440 × 440 matrix size (or STR = 1.89 with a 220 × 220 matrix size) together with a 3D CR improvement of 53% for the 10-mm sphere (24% using 220 × 220). CONCLUSION: The Vision exhibited improved NEMA performances compared to mCT. Using the proposed approach, the time acquisition could be divided by almost two, while keeping the same noise properties as that of mCT with a marked improvement of contrast recovery.
16
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Gaspar Delso, Sebastian Fürst, Björn Jakoby et al. · Journal of Nuclear Medicine · 2011 · 876 citations · Full text
Performance Characteristics of the Digital Biograph Vision PET/CT System
Joyce van Sluis, Johan de Jong, Jenny Schaar et al. · Journal of Nuclear Medicine · 2019 · 485 citations · Full text
Physical and clinical performance of the mCT time-of-flight PET/CT scanner
Bjoern Jakoby, Yanic Bercier, Maurizio Conti et al. · Physics in Medicine and Biology · 2011 · 483 citations
Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET
Georges El Fakhri, Suleman Surti, Cathryn M. Trott et al. · Journal of Nuclear Medicine · 2011 · 200 citations · Full text