Resuscitation Plus · 2020 · 16 citations · 34 references
MedicineCardiologyHemodynamic ManagementPhysiological Systems ModelingResuscitationCardiac Arrest ManagementCardiopulmonary ResuscitationCardiovascular MonitoringHemodynamic OptimizationHemodynamic ResuscitationResuscitation MonitoringAdaptive Control AlgorithmsCardiopulmonary Resuscitation FeedbackCompression BehaviorControl AlgorithmsMechanical Cardiopulmonary ResuscitationMechanical Cpr DevicesPost-resuscitation Physiologic MonitoringResuscitation Simulation
OBJECTIVES: We evaluated the feasibility of optimising coronary perfusion pressure (CPP) during cardiopulmonary resuscitation (CPR) with a closed-loop, machine-controlled CPR system (MC-CPR) that sends real-time haemodynamic feedback to a set of machine learning and control algorithms which determine compression/decompression characteristics over time. BACKGROUND: American Heart Association CPR guidelines (AHA-CPR) and standard mechanical devices employ a "one-size-fits-all" approach to CPR that fails to adjust compressions over time or individualise therapy, thus leading to deterioration of CPR effectiveness as duration exceeds 15-20 min. METHODS: CPR was administered for 30 min in a validated porcine model of cardiac arrest. Intubated anaesthetised pigs were randomly assigned to receive MC-CPR (6), mechanical CPR conducted according to AHA-CPR (6), or human-controlled CPR (HC-CPR) (10). MC-CPR directly controlled the CPR piston's amplitude of compression and decompression to maximise CPP over time. In HC-CPR a physician controlled the piston amplitudes to maximise CPP without any algorithmic feedback, while AHA-CPR had one compression depth without adaptation. RESULTS: MC-CPR significantly improved CPP throughout the 30-min resuscitation period compared to both AHA-CPR and HC-CPR. CPP and carotid blood flow (CBF) remained stable or improved with MC-CPR but deteriorated with AHA-CPR. HC-CPR showed initial but transient improvement that dissipated over time. CONCLUSION: Machine learning implemented in a closed-loop system successfully controlled CPR for 30 min in our preclinical model. MC-CPR significantly improved CPP and CBF compared to AHA-CPR and ameliorated the temporal haemodynamic deterioration that occurs with standard approaches.
34
Immediate Coronary Angiography in Survivors of Out-of-Hospital Cardiac Arrest
Christian Spaulding, Luc‐Marie Joly, Alain Rosenberg et al. · New England Journal of Medicine · 1997 · 955 citations · Full text
Medicine, Cardiology, Surgery +13
Mechanisms of blood flow during cardiopulmonary resuscitation.
Michael T. Rudikoff, W L Maughan, Mark B. Effron et al. · Circulation · 1980 · 442 citations · Full text
Jason A. Bartos, Brian Grunau, Claire Carlson et al. · Circulation · 2020 · 361 citations · Full text
Demetris Yannopoulos, Scott McKnite, Tom P. Aufderheide et al. · Resuscitation · 2005 · 330 citations