Publication | Open Access
Diagnostic performance of ultrasonography, dual-phase 99mTc-MIBI scintigraphy, early and delayed 99mTc-MIBI SPECT/CT in preoperative parathyroid gland localization in secondary hyperparathyroidism
37
Citations
31
References
2020
Year
The ability of early <sup>99m</sup>Tc-MIBI SPECT/CT to detect hyperplastic parathyroid glands in patients with SHPT is superior to that of US, dual-phase <sup>99m</sup>Tc-MIBI scintigraphy and delayed <sup>99m</sup>Tc-MIBI SPECT/CT; furthermore, dual-phase <sup>99m</sup>Tc-MIBI SPECT/CT is not essential.