Physics in Medicine and Biology · 2020 · 14 citations · 31 references
MedicineOncologyRadiation OncologyOptimizationRadiation DosimetryTreatment PlanningBrachytherapy DosimetryCancer Treatment PlanningDose OptimizationPatient Dose OptimizationPlan OptimizationRadiation Treatment PlanningDose Volume HistogramDose-volume Histogram AnalysisDwell Time OptimizationMixed-integer OptimizationMixed-integer Quadratic ProgrammingQuadratic Integer ProgrammingTreatment Plan OptimizationTreatment Planning Software
Abstract The purpose of this work was to develop an efficient quadratic mixed integer programming algorithm for high dose rate (HDR) brachytherapy treatment planning problems and integrate the algorithm into an open-source Monte Carlo based treatment planning software, RapidBrachyMCTPS. The mixed-integer algorithm yields a globally optimum solution to the dose volume histogram (DVH) based problem and, unlike other methods, is not susceptible to local minimum trapping. A hybrid linear-quadratic penalty model coupled to a mixed integer programming model was used to optimize treatment plans for 10 prostate cancer patients. Dose distributions for each dwell position were calculated with RapidBrachyMCTPS with type A uncertainties less than 0.2% in voxels within the planning target volume (PTV). The optimization process was divided into two parts. First, the data was preprocessed, in which the problem size was reduced by eliminating voxels that had negligible impact on the solution (e.g. far from the dwell position). Second, the best combination of dwell times to obtain a plan with the highest score was found. The dwell positions and dose volume constraints were used as input to a commercial mixed integer optimizer (Gurobi Optimization, Inc.). A penalty-based criterion was adopted for the scoring. The voxel-reduction technique successfully reduced the problem size by an average of 91%, without loss of quality. The preprocessing of the optimization process required on average 4 s and solving for the global maximum required on average 33 s. The total optimization time averaged 37 s, which is a substantial improvement over the ∼15 min optimization time reported in published literature. The plan quality was evaluated by evaluating dose volume metrics, including PTV D 90 , rectum and bladder D 1 cc and urethra D 0.1 cc . In conclusion, fast mixed integer optimization is an order of magnitude faster than current mixed-integer approaches for solving HDR brachytherapy treatment planning problems with DVH based metrics.
31
Geant4 developments and applications
John E. Allison, K. Amako, J. Apostolakis et al. · IEEE Transactions on Nuclear Science · 2006 · 6.9K citations · Full text
Luc Beaulieu, Åsa Carlsson Tedgren, Jean‐François Carrier et al. · Medical Physics · 2012 · 525 citations · Full text
Robert E. Drzymala, Radhe Mohan, Linda J. Brewster et al. · International Journal of Radiation Oncology*Biology*Physics · 1991 · 376 citations