ChemRxiv · 2020 · 153 citations · 9 references
MedicineInfectious DiseasesMolecular BiologyMolecular DiagnosticsMolecular VirologyVirologyInfectious Disease Molecular TestingNucleic Acid Amplification TestingPathogen DetectionPoint-of-care Molecular TestingPolymerase Chain ReactionRapid Diagnostic TestsCoronavirus DiagnosticsLoop-mediated Isothermal AmplificationPcr-based DetectionPolymerase Chain Reaction (Pcr) AssaysPolymerase Chain Reaction DetectionPolymerase Chain Reaction-based DiagnosticsPolymerase Chain Reaction-based TestingReverse Transcription Polymerase Chain Reaction (Rt-pcr)
The 2019 novel coronavirus (COVID-19) is a newly emerged strain that has never been found in humans before. At present, the laboratory-based reverse transcription-polymerase chain reaction (RT-PCR) is the main method to confirm COVID-19 infection. The intensification of the COVID-19 epidemic overwhelms limited clinical resources in particular, but not only, in developing countries, resulting in many patients not being tested for the infection and in large queues of potentially infected individuals waiting to be tested while providing a breeding ground for the disease. We describe here a rapid, highly sensitive, point-of-care, molecular test amenable for use at home, in the clinic, and at points of entry by minimally trained individuals and with minimal instrumentation. Our test is based on loop mediated isothermal amplification (COVID-19 LAMP) and for higher sensitivity on nested nucleic acid, two stage isothermal amplification (COVID-19 Penn-RAMP). Both tests can be carried out in closed tubes with either fluorescence or colorimetric (e.g., leuco crystal violet LCV) detection. COVID-19 LAMP performs on par with COVID-19 RT-PCR. COVID-19 RAMP has 10 fold better sensitivity than COVID-19 LAMP and COVID-19 RT-PCR when testing purified targets and 100 times better sensitivity than COVID-19 LAMP and COVID-19 RT-PCR when testing rapidly prepared sample mimics. Due to fortunate scarcity of COVID-19 infections in the USA, we were not able to test our assays and methods with patient samples. We hope that such tests will be carried out by colleagues in impacted countries. Our Closed-Tube Penn-RAMP has the potential to significantly reduce false negatives while being amenable to use with minimal instrumentation and training.
9
Xingzhi Xie, Zheng Zhong, Wei Zhao et al. · Radiology · 2020 · 2.1K citations · Full text
Eleanor Gaunt, Alison Hardie, Eric C. J. Claas et al. · Journal of Clinical Microbiology · 2010 · 745 citations · Full text
Veterinary Medicine, Infectious Diseases, Diagnostic Microbiology +16
Instrument-Free Point-of-Care Molecular Detection of Zika Virus
Jinzhao Song, Michael G. Mauk, Brent A. Hackett et al. · Analytical Chemistry · 2016 · 316 citations · Full text