PLoS ONE · 2020 · 35 citations · 19 references
Health ProfessionsEmergency Medical ServicesEmergency MedicineEmergencyPatient SafetyResuscitationBasic Life SupportCardiac Arrest ManagementCardiac EmergenciesCardiopulmonary ResuscitationPost-cardiac Arrest CareAutomated External Defibrillator UseCompression RatioMatched Control GroupOut-of-hospital Cardiac ArrestPatient Outcome EvaluationPatient Outcome MeasurementPatient Outcome MonitoringThoracic Impedance Monitoring
BACKGROUND: Laypersons' efforts to initiate basic life support (BLS) in witnessed Out-of-Hospital Cardiac Arrest (OHCA) remain comparably low within western society. Therefore, in order to shorten no-flow times in cardiac arrest, several police-based first responder systems equipped with automated external defibrillators (Pol-AED) were established in urban areas, which subsequently allow early BLS and AED administration by police officers. However, data on the quality of BLS and AED use in such a system and its impact on patient outcome remain scarce and inconclusive. METHODS: A total of 85 Pol-AED cases were randomly assigned to a gender, age and first rhythm matched non-Pol-AED control group (n = 170) in a 1:2 ratio. Data on quality of BLS were extracted via trans-thoracic impedance tracings of used AED devices. RESULTS: Comparing Pol-AED cases and the control group, we observed a similar compression rate per minute (p = 0.677) and compression ratio (p = 0.651), mirroring an overall high quality of BLS administered by police officers. Time to the first shock was significantly shorter in Pol-AED cases (6 minutes [IQR: 2-10] vs. 12 minutes [IQR: 8-17]; p<0.001). While Pol-AED was not associated with increased sustained return of spontaneous circulation (p = 0.564), a strong and independent impact on survival until hospital discharge (adj. OR: 1.85 [95%CI: 1.06-3.23; p = 0.030]) and a borderline significance for the association with favorable neurological outcome (adj. OR: 1.58 [95%CI: 0.96-2.89; p = 0.052) were observed. CONCLUSION: We were able to demonstrate an early start and a high quality of BLS and AED use in Pol-AED assessed OHCA cases. Moreover, the presence of Pol-AED care was associated with better patient survival and borderline significance for favorable neurological outcome.
19
Cardiac Arrest and Cardiopulmonary Resuscitation Outcome Reports
Ian Jacobs, Vinay Nadkarni, Jan Bahr et al. · Circulation · 2004 · 2.6K citations · Full text
Health Professions, Emergency Medicine, Critical Care Medicine +10
European Resuscitation Council Guidelines for Resuscitation 2015
Jasmeet Soar, Jerry P. Nolan, Bernd W. Böttiger et al. · Resuscitation · 2015 · 1.5K citations · Full text
Health Professions, Emergency Medical Services, Emergency Medicine +12