EJNMMI Radiopharmacy and Chemistry · 2020 · 13 citations · 5 references
MedicineNuclear MedicineOncologyDiagnostic Nuclear MedicineOncologic Nuclear MedicineTherapeutic Nuclear MedicineProstate Cancer ImagingRadiopharmaceuticalsAutomated Synthesis ModulesLymph Node MetastasesQuality Control ProceduresRadiochemical Purity AssessmentRadionuclide AnalysisRadionuclide Purity AssessmentRadiotracer SynthesisTechnetium-99m Labeling
Abstract Background Lymph node dissection is a therapeutic option for prostate cancer patients with a high risk of- or proven lymph node metastases. Radioguided surgery after intravenous injection of [ 99m Tc]Tc-PSMA could improve the selectivity of lymph node dissection. The aim of this project was to develop an automated synthesis method for [ 99m Tc]Tc-PSMA, using the disposables and chemicals used at our institute for [ 68 Ga]Ga-PSMA labeling. Furthermore, quality control procedures and validation results of the automated production of [ 99m Tc]Tc-PSMA conform cGMP and cGRPP are presented. Methods [ 99m Tc]Tc-PSMA is produced fully automatic with a Scintomics synthesis module. Quality control procedures are described and performed for: activity, labeling yield, visual inspection, pH measurement, sterility and endotoxin determination, radionuclide purity, radiochemical purity ( 99m Tc-colloids, unbound [ 99m Tc]pertechnetate, and other impurities), and HEPES content. Three batches of [ 99m Tc]Tc-PSMA were prepared on three separate days for validation and stability testing at 0, 4, 6, and 24 h. Results [ 99m Tc]Tc-PSMA can be successfully manufactured automatically within a [ 68 Ga]Ga-PSMA workflow with the addition of only [ 99m Tc]pertechnetate and stannous chloride. The radiochemical purity after production was highly reproducible (96.3%, 97.6%, and 98.2%) and remained > 90% (required for patient administration) up to 6 h later. Conclusion A fully automated labeling procedure with corresponding quality control methods for production of [ 99m Tc]Tc-PSMA is presented, which is validated according to cGMP and cGRPP guidelines and can be implemented in a GMP environment. The produced [ 99m Tc]Tc-PSMA is stable for up to 6 h. The presented procedure is almost identical to the automated production of [ 68 Ga]Ga-PSMA and can therefore be implemented expediently if a workflow for [ 68 Ga]Ga-PSMA is already in place.
5
Stephanie Robu, Margret Schottelius, Matthias Eiber et al. · Journal of Nuclear Medicine · 2016 · 228 citations · Full text
Medicine, Nuclear Medicine, Oncology +17
Philip H. Elsinga, Sergio Todde, Iván Peñuelas et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2010 · 154 citations · Full text