Publication | Closed Access
Seismic Retrofit of Existing Masonry Buildings through Inter-story Isolation System: A Case Study and General Design Criteria
39
Citations
15
References
2020
Year
EngineeringMasonry StructuresArchitectural EngineeringSeismic RetrofitStructural OptimizationStructural SystemBuilding DesignStructural EngineeringBuilt EnvironmentSeismic AnalysisIrregular Masonry BuildingsVibration IsolationStructural DynamicIsolated Vertical AdditionEarthquake EngineeringExisting Masonry BuildingsRetrofittingGlobal Seismic ResponseCivil EngineeringSeismic IsolationCase StudyStructural MechanicsConstruction Engineering
This paper investigates the potentials of inter-story isolation systems (IIS) for retrofitting irregular masonry buildings by means of an isolated vertical addition realised on the roof of the existing structure. By assuming a case study, a wide parametric analysis is firstly carried out on lumped-masses model for identifying the dynamic properties of the isolated superstructure that minimizes the global seismic response. Hence, a 3D FE model is adopted for the detailed design and analysis of the IIS structure, with different solutions, in order to regularize the global seismic response of the IIS complex. Finally, some general design criteria are suggested.