RSC Advances · 2020 · 32 citations · 29 references
EngineeringMaterials EngineeringMaterials ScienceMicroelectromechanical SystemsPolymer EngineeringSensorsAcoustic MeasurementAcoustic SensingAcoustic Sensing SystemsAcoustic SensorsHumidity SensorsSensor MaterialsExposure Time DependenceExposure-time RelationshipInterferencePolymer SensorsPolymer-based Humidity SensorsSurface Acoustic Wave Gas SensorsSurface Acoustic Wave Humidity SensorsSurface Acoustic Wave Sensors
. Under different temperature (0-50 C°) and humidity (30-80% RH) conditions, CEES was detected by the fabricated SAW sensor coated with PECH, the frequency shifts were measured and the performance of the sensor was evaluated. The results proved that temperature and humidity were the most important factors to influence the performance of SAW sensors; with the decreasing of temperature and the increasing of humidity, there would be larger frequency shifts. In the interference experiments, it was found that most gases existing in the environment in high concentrations would not influence the detection of CEES. Then, the SAW sensor having been fabricated was kept under the conditions of 25 °C and 35% RH for 18 months to further verify the quality, and CEES was detected every so many months. It proved that the performance of the sensor would decrease about 16.39% after 18 months. Although it reflected the attenuation of the sensor to some extent, the sensor was still in good condition. Additionally, the related mechanisms were also discussed.
29
Jay W. Grate, Arthur W. Snow, David S. Ballantine et al. · Analytical Chemistry · 1988 · 241 citations
Surface acoustic wave-based gas sensors
W. Jakubik · Thin Solid Films · 2011 · 172 citations