42nd AIAA Aerospace Sciences Meeting and Exhibit · 2004 · 12 citations · 0 references
EngineeringAerospace EngineeringMechanical EngineeringComputational Fluid DynamicsFluid DynamicsHeat TransferEnthalpy MeasurementHeat Transfer AnalysisHeat Transfer FundamentalsHeat Transfer In FluidsHeat Transfer ModelingArc Jet TestingCfd SimulationComputational Fluid Dynamics ValidationEnthalpyEnthalpy BalanceEnthalpy EstimationHeat Transfer RateOperating Conditions
Four experimental methods of determining the enthalpy of the flow in an arc-jet facility that is, the heat balance method, the sonic throat method, the heat transfer method, and the emission-spectroscopic method, are compared with a computational fluid dynamics (CFD) solution. The comparison is made for the Interaction Heating Facility of NASA Ames Research Center for one operating condition. The mass-averaged enthalpy values determined by the heat-balance method and the sonic throat method are 28.7 and 28.8 MJ/kg, respectively. The lower bound of the centerline enthalpy value determined by the heat transfer rate method is 30.5 MJ/kg. The spectrometric method resulted in the centerline enthalpy value of 40.6 MJ/kg. The CFD solution yields the centerline and the average enthalpy values at the nozzle throat of 41.0 and 27.0 MJ/kg, respectively.