Gut · 2020 · 10 citations · 21 references
MedicineClinical SciencesOncologyCancer ScreeningGastroenterologyGastrointestinal OncologyCancer Early DetectionColorectal CancerGastrointestinal AssessmentGastrointestinal EndoscopyGastrointestinal ImagingColonoscopy ScreeningColorectal AdenomasColorectal Cancer PrevalenceColorectal Cancer PreventionColorectal Cancer ScreeningColorectal Cancer Screening CoverageEndoscopic ScreeningLower Gastrointestinal Endoscopy
OBJECTIVES: Adenoma detection rate (ADR) is an important quality marker at lower GI endoscopy. Higher ADRs are associated with lower postcolonoscopy colorectal cancer rates. The English flexible sigmoidoscopy (FS) screening programme (BowelScope), offers a one-off FS to individuals aged 55 years. However, variation in ADR exists. Large studies have demonstrated improved ADR using Endocuff Vision (EV) within colonoscopy screening, but there are no studies within FS. We sought to test the effect of EV on ADR in a national FS screening population. DESIGN: BowelScope: Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities was a multicentre, randomised controlled trial involving 16 English BowelScope screening centres. Individuals were randomised to Endocuff Vision-assisted BowelScope (EAB) or Standard BowelScope (SB). ADR, polyp detection rate (PDR), mean adenomas per procedure (MAP), polyp characteristics and location, participant experience, procedural time and adverse events were measured. Comparison of ADR within the trial with national BowelScope ADR was also undertaken. RESULTS: 3222 participants were randomised (53% male) to receive EAB (n=1610) or SB (n=1612). Baseline demographics were comparable between arms. ADR in the EAB arm was 13.3% and that in the SB arm was 12.2% (p=0.353). No statistically significant differences were found in PDR, MAP, polyp characteristics or location, participant experience, complications or procedural characteristics. ADR in the SB control arm was 3.1% higher than the national ADR. CONCLUSION: EV did not improve BowelScope ADR when compared with SB. ADR in both arms was higher than the national ADR. Where detection rates are already high, EV is unable to improve detection further. TRIAL REGISTRATION NUMBERS: NCT03072472, ISRCTN30005319 and CPMS ID 33224.
21
Janus Christian Jakobsen, Christian Gluud, Jørn Wetterslev et al. · BMC Medical Research Methodology · 2017 · 2.8K citations · Full text
Understanding the Hawthorne effect
P. Sedgwick, Nan Greenwood · BMJ · 2015 · 808 citations · Full text
[Principles and practice of mass screening for disease].
J M Wilson, Y G Jungner · PubMed · 1968 · 770 citations
Colonoscopy quality measures: experience from the NHS Bowel Cancer Screening Programme
Thomas J.W. Lee, Matthew D. Rutter, R G Blanks et al. · Gut · 2011 · 325 citations