Atmospheric measurement techniques · 2020 · 68 citations · 40 references
Natural SciencesChemistryAnalytical ChemistryMass Spectrometric AnalysisSpectroscopyIonization TechniquesMass SpectrometryPhotoelectron SpectroscopyUltraviolet InstrumentationUltraviolet SpectroscopyAnalytical Detection LimitsIon Source DesignIon SourcesIonizationPhotoionization ProcessesVacuum TechnologyVacuum Ultraviolet Spectroscopy
Abstract. A new ion source (IS) utilizing vacuum ultraviolet (VUV) light is developed and characterized for use with iodide–chemical ionization mass spectrometers (I−-CIMS). The VUV-IS utilizes a compact krypton lamp that emits light at two wavelengths corresponding to energies of ∼10.030 and 10.641 eV. The VUV light photoionizes either methyl iodide (ionization potential, IP = 9.54 ± 0.02 eV) or benzene (IP = 9.24378 ± 0.00007 eV) to form cations and photoelectrons. The electrons react with methyl iodide to form I−, which serves as the reagent ion for the CIMS. The VUV-IS is characterized by measuring the sensitivity of a quadrupole CIMS (Q-CIMS) to formic acid, molecular chlorine, and nitryl chloride under a variety of flow and pressure conditions. The sensitivity of the Q-CIMS, with the VUV-IS, reached up to ∼700 Hz pptv−1, with detection limits of less than 1 pptv for a 1 min integration period. The reliability of the Q-CIMS with a VUV-IS is demonstrated with data from a month-long ground-based field campaign. The VUV-IS is further tested by operation on a high-resolution time-of-flight CIMS (TOF-CIMS). Sensitivities greater than 25 Hz pptv−1 were obtained for formic acid and molecular chlorine, which were similar to that obtained with a radioactive source. In addition, the mass spectra from sampling ambient air was cleaner with the VUV-IS on the TOF-CIMS compared to measurements using a radioactive source. These results demonstrate that the VUV lamp is a viable substitute for radioactive ion sources on I−-CIMS systems for most applications. In addition, initial tests demonstrate that the VUV-IS can be extended to other reagent ions by the use of VUV absorbers with low IPs to serve as a source of photoelectrons for high IP electron attachers, such as SF6-.
40
A large atomic chlorine source inferred from mid-continental reactive nitrogen chemistry
Joel A. Thornton, James P. Kercher, Theran P. Riedel et al. · Nature · 2010 · 712 citations · Full text
Ben H. Lee, Felipe D. Lopez‐Hilfiker, Claudia Mohr et al. · Environmental Science & Technology · 2014 · 690 citations
F. L. Eisele, David J. Tanner · Journal of Geophysical Research Atmospheres · 1993 · 542 citations