Chinese Journal of Cancer Research · 2020 · 24 citations · 22 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingCancer DetectionComputed TomographyMolecular Imaging In OncologyOncologic Nuclear ImagingTumor CharacterizationTumor ImagingKi-67 ImagingKi-67 ImmunostainingKi-67 Labeling IndexLung AdenocarcinomaLung Tumor ImagingMolecular Diagnostic MarkersSpectral Computed TomographySpectral Imaging
OBJECTIVE: To explore the correlation between the spectral computed tomography (CT) imaging parameters and the Ki-67 labeling index in lung adenocarcinoma. METHODS: Spectral CT imaging parameters [iodine concentrations of lesions (ICLs) in the arterial phase (ICLa) and venous phase (ICLv), normalized IC in the aorta (NICa/NICv), slope of the spectral HU curve (λHUa/λHUv) and monochromatic CT number enhancement on 40 keV and 70 keV images (CT40keVa/v, CT70keVa/v)] in 34 lung adenocarcinomas were analyzed, and common molecular markers, including the Ki-67 labeling index, were detected with immunohistochemistry. Different Ki-67 labeling indexes were measured and grouped into four grades according to the number of positive-stained cells (grade 0, ≤1%; 1%<grade 1≤10%; 10%<grade 2≤30%; and grade 3, >30%). One-way analysis of variance (ANOVA) was used to compare the four different grades, and the Bonferroni method was used to correct the P value for multiple comparisons. A Spearman correlation analysis was performed to further research a quantitative correlation between the Ki-67 labeling index and spectral CT imaging parameters. RESULTS: CT40keVa, CT40keVv, CT70keVa and CT70keVv increased as the grade increased, and CT70keVa and CT70keVv were statistically significant (P<0.05). These four parameters and the Ki-67 labeling index showed a moderate positive correlation with lung adenocarcinoma nodules. ICL, NIC and λHU in the arterial and venous phases were not significantly different among the four grades. CONCLUSIONS: The spectral CT imaging parameters CT40keVa, CT40keVv, CT70keVa and CT70keVv gradually increased with Ki-67 expression and showed a moderate positive correlation with lung adenocarcinomas. Therefore, spectral CT imaging parameter-enhanced monochromatic CT numbers at 70 keV may indicate the extent of proliferation of lung adenocarcinomas.
22
Persistent Pure Ground-Glass Opacity Lung Nodules ≥ 10 mm in Diameter at CT Scan
Hyun-ju Lim, Soomin Ahn, Kyung Soo Lee et al. · CHEST Journal · 2013 · 256 citations
Differential Diagnosis of Ground-Glass Opacity Nodules
Koei Ikeda, Kazuo Awai, Takeshi Mori et al. · CHEST Journal · 2007 · 165 citations
Ji Ye Son, Ho Yun Lee, Jae‐Hun Kim et al. · European Radiology · 2015 · 129 citations