A Low-Cost DAC System for On-Site PD Testing of HV Cables Based on ACRF and Capacitor Bank

Yuxin Lu, Xuefeng Zhao, Yingjie Geng, Hongjie Li, Xiaolong Xu, Weisheng He, Saike Yang, Yuan Yan

IEEE Transactions on Power Delivery · 2020 · 14 citations · 5 references

Concepts

Abstract

Damped AC (DAC) technique has proven to be one of the most acceptable techniques for on-site partial discharge (PD) detection. However, the expensive high-voltage switches, used in the DAC system, impede the further spread of the technique. This letter presents a low-cost DAC system for PD test of high-voltage cables. The DAC voltage is generated by the frequency-tuned series resonant technique and two cost-effective switches which have relatively low rated voltage. Since the system uses a capacitor bank, high input power is not necessary. This letter describes the design and implementation of the system. An experimental study and an on-site test validate the effectiveness of the proposed system.

References

5