Evaluation of Retinal Nerve Fiber Layer Thickness, Electroretinogram and Visual Evoked Potential in Patients with Alzheimer’s Disease

Qi Zhe Ngoo, Wan Hazabbah Wan Hitam, Asrenee Ab Razak

Journal of Ophthalmology · 2019 · 62 citations · 23 references

DOIFull text

Open access

Concepts

Abstract

Objective . To study the retinal nerve fibre layer (RNFL) thickness and visual electrophysiology testing in patients with Alzheimer’s disease (AD). Methods . A cross-sectional, hospital-based study: 25 AD subjects and 25 controls were recruited. Candidates who fulfil the criteria with normal ocular examinations were made to proceed with scanning laser polarimetry, pattern electroretinogram (PERG), and pattern visual evoked potential (PVEP) examinations of the right eye. RNFL thickness, PERG, and PVEP readings were evaluated. Results . In AD, the mean of average RNFL thickness was 45.28 μ m, SD = 3.61, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>), while the superior RNFL thickness was 54.44 μ m, SD = 2.85, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M3"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M4"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>) and inferior RNFL thickness was 47.11 μ m, SD = 4.52, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M5"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M6"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>). For PERG, the mean P50 latency was 63.88 ms, SD = 7.94, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M7"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M8"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>) and the mean amplitudes of P50 waves were 1.79 μ V, SD = 0.64, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M9"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M10"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>) and N95 waves were 2.43 μ V, SD = 0.90, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M11"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M12"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>). For PVEP, the mean latency of P100 was 119.00 ms, SD = 9.07, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M13"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M14"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>), while the mean latency of N135 was 145.20 ms, SD = 8.53, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M15"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M16"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>). The mean amplitude of P100 waves was 3.71 μ V, SD = 1.60, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M17"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M18"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>), whereas the mean amplitude of N135 waves was 3.67 μ V, SD = 2.02, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M19"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M20"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>). RNFL thickness strongly correlates with PERG readings, with P50 latency R = 0.582, R 2 = 0.339, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M21"><mml:mrow><mml:mi>P</mml:mi><mml:mo>=</mml:mo><mml:mn>0.002</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M22"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>), amplitude of P50 wave at R = 0.749, R 2 = 0.561, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M23"><mml:mrow><mml:mi>P</mml:mi><mml:mo>≤</mml:mo><mml:mn>0.001</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M24"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>), and amplitude of N95 wave at R = 0.500, R 2 = 0.250, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M25"><mml:mrow><mml:mi>P</mml:mi><mml:mo>=</mml:mo><mml:mn>0.011</mml:mn></mml:mrow></mml:math> (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M26"><mml:mrow><mml:mi>P</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>). No significant difference and correlation were observed on PVEP readings. Conclusion . The mean of the average, superior and inferior RNFL thickness were significantly lower in the AD group compared with control. There is also significant difference of PERG and PVEP parameters between AD and controls. Regression analysis showed average RNFL thickness having significantly linear relationship with the PERG parameters.

References

23