Scientific Reports · 2019 · 30 citations · 15 references
EngineeringBioengineeringBiomedical EngineeringPhysiological Systems ModelingPulmonologyVentilationLung VolumesMechanical VentilationPulmonary MechanicsRespiratory BiomechanicsRespiratory System ModelingBreathing MechanicsEx Vivo ModelsLung Mechanics ModelingPressure - Flow CharacteristicsRespiratory Mechanics During DiseaseRespiratory Mechanics MeasurementRespiratory System MechanicsVentilatory Dynamics
Abstract Simulation models in respiratory research are increasingly used for medical product development and testing, especially because in-vivo models are coupled with a high degree of complexity and ethical concerns. This work introduces a respiratory simulation system, which is bridging the gap between the complex, real anatomical environment and the safe, cost-effective simulation methods. The presented electro-mechanical lung simulator, xPULM, combines in - silico , ex-vivo and mechanical respiratory approaches by realistically replicating an actively breathing human lung. The reproducibility of sinusoidal breathing simulations with xPULM was verified for selected breathing frequencies (10–18 bpm) and tidal volumes (400–600 ml) physiologically occurring during human breathing at rest. Human lung anatomy was modelled using latex bags and primed porcine lungs. High reproducibility of flow and pressure characteristics was shown by evaluating breathing cycles (n Total = 3273) with highest standard deviation |3σ| for both, simplified lung equivalents ( $${{\boldsymbol{\mu }}}_{\dot{{\bf{V}}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msub><mml:mrow><mml:mi>µ</mml:mi></mml:mrow><mml:mrow><mml:mover><mml:mi>V</mml:mi><mml:mo>̇</mml:mo></mml:mover></mml:mrow></mml:msub></mml:math> = 23.98 ± 1.04 l/min, μ P = −0.78 ± 0.63 hPa) and primed porcine lungs ( $${{\boldsymbol{\mu }}}_{\dot{{\bf{V}}}}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msub><mml:mrow><mml:mi>µ</mml:mi></mml:mrow><mml:mrow><mml:mover><mml:mi>V</mml:mi><mml:mo>̇</mml:mo></mml:mover></mml:mrow></mml:msub></mml:math> = 18.87 ± 2.49 l/min, μ P = −21.13 ± 1.47 hPa). The adaptability of the breathing simulation parameters, coupled with the use of porcine lungs salvaged from a slaughterhouse process, represents an advancement towards anatomically and physiologically realistic modelling of human respiration.
15
Simulation in healthcare education: A best evidence practical guide. AMEE Guide No. 82
Ivette Motola, Luke Devine, Hyun Soo Chung et al. · Medical Teacher · 2013 · 1.2K citations · Full text
Modelling inhaled particle deposition in the human lung—A review
W. Hofmann · Journal of Aerosol Science · 2011 · 484 citations
Simon Festing, Robin Wilkinson · EMBO Reports · 2007 · 309 citations · Full text