IEEE Transactions on Neural Systems and Rehabilitation Engineering · 2019 · 123 citations · 63 references
EducationKinesiologyPhysiologyMachine LearningMovement AnalysisStatistical LearningGait AnalysisGait AssessmentGait BiomechanicsGait EvaluationLocomotion AnalysisCustom-made InsolesGaitGait Spatiotemporal ParametersHuman Gait AnalysisStride LengthSupport Vector RegressionSupport Vector Regression SurrogatesWearable Sensors
Wearable sensors are proposed as low‑cost, portable alternatives for real‑time gait analysis, but their moderate accuracy currently limits widespread adoption. This study demonstrates that support vector regression models can accurately estimate stride length, velocity, and foot clearance from custom instrumented insoles during walking and running. The authors evaluated the models on 14 healthy subjects in two sessions of 6‑minute treadmill walking and running at 85 % and 115 % of preferred speed, comparing insole measurements with reference laboratory equipment. The SVR models achieved excellent intraclass correlation coefficients and mean absolute errors of 1.3–5.1 % across gait parameters, confirming machine‑learning regression as a promising approach to enhance wearable sensor accuracy.
Wearable sensors have been proposed as alternatives to traditional laboratory equipment for low-cost and portable real-time gait analysis in unconstrained environments. However, the moderate accuracy of these systems currently limits their widespread use. In this paper, we show that support vector regression (SVR) models can be used to extract accurate estimates of fundamental gait parameters (i.e., stride length, velocity, and foot clearance), from custom-engineered instrumented insoles (SportSole) during walking and running tasks. Additionally, these learning-based models are robust to inter-subject variability, thereby making it unnecessary to collect subject-specific training data. Gait analysis was performed in N=14 healthy subjects during two separate sessions, each including 6-minute bouts of treadmill walking and running at different speeds (i.e., 85% and 115% of each subject's preferred speed). Gait metrics were simultaneously measured with the instrumented insoles and with reference laboratory equipment. SVR models yielded excellent intraclass correlation coefficients (ICC) in all the gait parameters analyzed. Percentage mean absolute errors (MAE%) in stride length, velocity, and foot clearance obtained with SVR models were 1.37%±0.49%, 1.23%±0.27%, and 2.08%±0.72% for walking, 2.59%±0.64%, 2.91%±0.85%, and 5.13%±1.52% for running, respectively. These findings provide evidence that machine learning regression is a promising new approach to improve the accuracy of wearable sensors for gait analysis.
63