ACS Sensors · 2019 · 53 citations · 19 references
EngineeringBioengineeringBiotechnologyAnalytical ChemistryBiomemsBiosensorsMagnetic SeparationMicrofluidic BiosensorsMicrofluidic Device FabricationMicrofluidic DevicesMicrofluidic SystemsMicrofluidicsDna Hybridization DetectionMicrofluidic Diagnostic DevicesMicrofluidic Diagnostic PlatformsMicrofluidic SensingMicroparticlesSelectivityWater HardnessWater Safety Monitoring
Lead contamination in drinking water is a primary concern in public health, but it is difficult to monitor by end-users. Here, we provide a rapid and power-free microfluidic particle dam which enables visual quantification of lead ions (Pb2+) by the naked eye. GR-5 DNAzyme with extended termini can connect magnetic microparticles (MMPs) and polystyrene microparticles (PMPs) by DNA hybridization, forming “MMPs-GR-5-PMPs”. When Pb2+ is present, GR-5 is cleaved, resulting in an increasing number of free PMPs. To visually count the free PMPs, the solution is loaded to a capillary-driven microfluidic device that consists of a magnetic separator to remove the MMPs-GR-5-PMPs, followed by a particle dam that traps and accumulates the free PMPs into a visual bar with growing length proportional to the concentration of lead. The device achieved a limit of detection at 2.12 nM (0.44 ppb), high selectivity (>20,000-fold) against other metal ions, high tolerance to different pH and water hardness, and is compatible with tap water with a high recovery rate, enabling visual quantification and user-friendly interface for rapid screening of water safety.
19
A highly selective lead sensor based on a classic lead DNAzyme
Tian Lan, Kimberly Furuya, Yi Lu · Chemical Communications · 2010 · 273 citations · Full text