Lab on a Chip · 2019 · 19 citations · 40 references
We report a bifurcated continuous field-flow fractionation (BCFFF) chip for high-yield and high-throughput (20 min) extraction of nucleic acids from physiological samples. The design uses a membrane ionic transistor to sustain low-ionic strength in a localized region at a junction, such that the resulting high field can selectively isolate high-charge density nucleic acids from the main flow channel and insert them into a standardized buffer in a side channel that bifurcates from the junction. The high local electric field and the bifurcated field-flow design facilitate concentration reduction of both divalent cation (Ca<sup>2+</sup>) and molecular PCR inhibitors by more than two orders of magnitude, even with high-throughput continuous loading. The unique design with a large (>20 mM mm<sup>-1</sup>) on-chip ionic-strength gradient allows miniaturization into a high-throughput field-flow fractionation chip that can be integrated with upstream lysing and downstream PCR/sensor modules for various nucleic acid detection/quantification applications. A concentration-independent 85% yield for extraction and an overall post-PCR yield exceeding 60% are demonstrated for a 111 bp dsDNA in 10 μL of human plasma, compared to no amplification with the raw sample. A net yield four times larger than a commercial extraction kit is demonstrated for miR-39 in human plasma.
40
The free solution mobility of DNA
Nancy C. Stellwagen, Cecilia Gelfi, Pier Giorgio Righetti · Biopolymers · 1997 · 307 citations
An integrated paper-based sample-to-answer biosensor for nucleic acid testing at the point of care
Jane Ru Choi, Jie Hu, Ruihua Tang et al. · Lab on a Chip · 2015 · 286 citations