Clinical Oral Investigations · 2019 · 39 citations · 35 references
DentistryDental Materials ScienceEsthetic DentistryDental MaterialsProsthodontic BiomaterialsProsthodontic MaterialsCeramic RestorationsCrown MaterialsDental CementsDental CeramicsDental PolymersLuting CementsCeramic Restoration Marginal FitDental CrownsMarginal DiscrepancyPolymer-based CrownsPolymer-infiltrated Ceramic NetworksPolymer-infiltrated Ceramic RestorationsResin Infiltration MaterialsResin-based Dental Materials
Abstract Objectives The study evaluates the influence of two spacer settings and three resin luting materials on the marginal and internal fit of polymer-infiltrated ceramic network (PICN) material crowns manufactured using a complete digital workflow. Methods Optical impressions of fifty identical dies were performed using the 3M scanner (software version 5.0.2). Twenty crowns were designed using Ceramill Mind (version 3.4.10.1163), from which ten with spacer setting of 50 μm (G1) and ten with 80 μm (G2). Thirty crowns (spacer setting of 50 μm) were divided into three groups corresponding to the resin materials used as follows: RelyX Unicem (RX), Variolink Esthetic (VLE), and Nexus 3 (NX3). All crowns were milled from Vita Enamic blocks. After micro-CT scanning, absolute marginal discrepancy (AMD), internal gap (IG), total cement space volume (TCV), and marginal porosities (VP) were measured. Results Significant difference was detected on the VP between the RX and NX3 group ( p = 0.033). The mean values of all parameters were the following: AMD (μm): G1 182.6, G2 253.7, RX 210.8, VLE 195.5, NX3 186.6; IG (μm): G1 215.6, G2 173.1, RX 171.1, VLE 198.6, NX3 203; TCV (mm 3 ): G1 22.9, G2 20.49, RX 17.57, VLE 17.49, NX3 20.59; VP (mm 3 ): G1 0.26, G2 0.34, RX 0.32, VLE 0.46, NX3 0.54. Conclusions Fit of PICN material crowns was not significantly influenced by increasing the spacer settings and cementation with different resin materials. Additionally, RelyX Unicem showed significantly less porosities as compared with Nexus3. Clinical relevance Both 50 μm and 80 μm virtual spacer settings can be suggested for the manufacture of PICN crowns when Ceramill Mind (version 3.4.10.1163) is used. Furthermore, a self-adhesive system can be recommended for the cementation.
35
Fiji: an open-source platform for biological-image analysis
Johannes Schindelin, Ignacio Arganda‐Carreras, Erwin Frise et al. · Nature Methods · 2012 · 70.9K citations
NIH Image to ImageJ: 25 years of image analysis
Caroline A Schneider, Wayne Rasband, Kevin W. Eliceiri · Nature Methods · 2012 · 65.2K citations
The estimation of cement film thickness by an in vivo technique
J W McLean, Fraunhofer von · BDJ · 1971 · 1.4K citations
Clinical fit of Procera AllCeram crowns
Klaus Boening, Burkhard H. Wolf, Annette Schmidt et al. · Journal of Prosthetic Dentistry · 2000 · 286 citations