PLoS ONE · 2019 · 14 citations · 10 references
MedicineOrthopedic SurgerySurgeryMedical RoboticsOrthopedicsSpine SurgeryComputer-aided Surgical Guide DesignIntraoperative NavigationMinimally Invasive Spine SurgeryRobot-assisted SurgerySurgical RoboticsComputer-guided SurgeryNavigation-assisted Implant PlacementNavigation-assisted SurgeryNavigation-guided Spine SurgeryNavigation-guided SurgeryRobotic-assisted Spinal SurgeryRobotic-assisted Spine SurgeryTomography
Recent technical developments have resulted in robotic-assisted pedicle screw placement techniques. However, the use of robotic-assisted navigational techniques is still subject to controversy. This study aims to assess the accuracy and safety of a self-developed navigation system, the point spine navigation system (PSNS), for robotic-assisted pedicle screw placement surgery. Fifty-nine pedicle screws were implanted in three porcine vertebrae at the T6-T10 and L1-L5 levels, with the assistance of the PSNS. The navigation and planning system provides virtual surgical guide images, including sagittal, coronal, axial, oblique planes, and customized three-dimensional reconstructions for each vertebra to establish accurate pedicle screw trajectories and placement tracts. After pedicle screw placement, post-operative spiral computer tomographic scans were performed and screws were evaluated using the Gertzbein-Robbins classification. Differences between the actual pedicle screw position and pre-operative planning paths, including the angle, shortest distance, and entry trajectory were recorded. The 59 pedicle screw placements were all within a safe zone, and there was no spinal canal perforation or any other damage under postoperative computed tomography image data. Fifty-one screws were categorized as group A, seven screws were noted as group B, and one screw was identified as group E under the Gertzbein-Robbins classification. The mean entry point deviation was 2.71 ± 1.72°, mean trajectory distance was 1.56 ± 0.66 mm, and average shortest distance between two paths was 0.96 ± 0.73 mm. Pedicle placement remains a challenging procedure with high reported incidences of nerve and vascular injuries. The implementation of a robotic-assisted navigational system yields an acceptable level of accuracy and safety for the pedicle screw placement surgery.
10
Accuracy of Pedicular Screw Placement In Vivo
Stanley D. Gertzbein, STEPHEN E. ROBBINS · Spine · 1990 · 1.4K citations
Dennis P. Devito, Leon Kaplan, Rupert Dietl et al. · Spine · 2010 · 410 citations
Sven Rainer Kantelhardt, Ramón Martínez, Stefan Baerwinkel et al. · European Spine Journal · 2011 · 407 citations · Full text
Florian Röser, Marcos Tatagiba, Gottlieb Maier · Neurosurgery · 2012 · 314 citations
Medicine, Neurosurgery, Surgery +14
Isador H. Lieberman, Mitchell Hardenbrook, Jeffrey C. Wang et al. · Journal of Spinal Disorders & Techniques · 2011 · 156 citations