Second generation, sirolimus‐eluting, bioresorbable Tyrocore scaffold implantation in patients with ST‐segment elevation myocardial infarction: Baseline OCT and 30‐day clinical outcomes – A FANTOM STEMI pilot study

Mariusz Tomaniak, Dorota Ochijewicz, Jakub Maksym, Tomasz Roleder, Martyna Zaleska, Klaudia Proniewska, Grzegorz Opolski, Janusz Kochman

Catheterization and Cardiovascular Interventions · 2019 · 14 citations · 10 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: There is paucity of data on acute performance of Fantom (REVA Medical, CA), a second generation sirolimus-eluting bioresorbable scaffold (BRS), in ST-segment elevation myocardial infarction (STEMI) patients undergoing primary percutaneous coronary intervention. The aim of this study was to evaluate safety and efficacy of the Fantom BRS in the acute setting of STEMI characterized by thrombogenic milieu. METHODOLOGY: Ten STEMI patients treated with a sirolimus-eluting Fantom BRS were enrolled into prospective, observational study. The scaffold sizing, positioning, and optimization were optical coherence tomography (OCT) guided. The primary end-point was the device-oriented composite endpoint (DOCE), additionally angiographic and OCT analysis were performed. RESULTS: The primary-end point, defined as DOCE, did not occur in any patient within the 30-day follow-up. The procedural and angiographic success rates were both 100%, there was no case of scaffold thrombosis, target lesion revascularization nor death. In QCA, an in-device minimum lumen diameter was 2.89 ± 0.24 mm and the residual diameter stenosis was 3.56 ± 3.17%. OCT revealed an incomplete scaffold apposition in five patients with an average of seven malapposed struts per scaffold and mean distance of 120 ± 30 μm. There was no proximal edge dissection, the distal edge dissection was recorded in one patient. CONCLUSIONS: This is the first pilot study evaluating safety and efficacy of the Fantom BRS, a second generation fully bioresorbable coronary scaffold, in STEMI patients undergoing primary PCI with OCT guidance. Fantom BRS showed adequate safety and efficacy in the acute 30-day angiographic, OCT, and clinical follow-up.

References

10

ACC/AHA guidelines for percutaneous coronary intervention (revision of the 1993 PTCA guidelines)—executive summary21When citing this document, the American College of Cardiology and the American Heart Association would appreciate the following citation format: Smith SC, Jr, Dove JT, Jacobs AK, Kennedy JW, Kereiakes D, Kern MJ, Kuntz RE, Popma JJ, Schaff HV, Williams DO. ACC/AHA guidelines for percutaneous coronary intervention: executive summary and recommendations: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Revise the 1993 Guidelines for Percutaneous Transluminal Coronary Angioplasty). J Am Coll Cardiol 2001;37:2215–38.22Address for reprints: a single reprint of this document is available by calling 800-253-4636 (US only) or writing the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699. This document (reprint no. 71-0205), as well as the companion full-text guideline (reprint no. 71-0206), are available on the ACC Web site at www.acc.organd the AHA Web site at http://www.americanheart.org. To purchase additional reprints (specify version): up to 999 copies, call 800-611-6083 (US only) or fax 413-665-2671; 1000 or more copies, call 214-706-1466, fax 214-691-6342; or E-mail: pubauth@heart.org.

Sidney C. Smith, James Dove, Alice K. Jacobs et al. · Journal of the American College of Cardiology · 2001 · 644 citations

, , +13