Resonant scattering and diffraction beamline P09 at PETRA III

J. Strempfer, Sonia Francoual, D. Reuther, D. K. Shukla, Audun Skaugen, H. Schulte‐Schrepping, T. Kracht, H. Franz

Journal of Synchrotron Radiation · 2013 · 107 citations · 22 references

DOIFull text

Open access

Concepts

Abstract

The resonant scattering and diffraction beamline P09 at PETRA III is designed for X-ray experiments requiring small beams, energy tunability, variable polarization and high photon flux. It is highly flexible in terms of beam size and offers full higher harmonic suppression. A state-of-the-art double phase-retarder set-up provides variable linear or circular polarization. A high-precision Psi-diffractometer and a heavy-load diffractometer in horizontal Psi-geometry allow the accommodation of a wide variety of sample environments. A 14 T cryo-magnet is available for scattering experiments in magnetic fields.

References

22