Journal of Cardiovascular Magnetic Resonance · 2019 · 12 citations · 31 references
MedicineCardiologyPharmacologyCardiac Nuclear MedicineNuclear CardiologyPharmacodynamicsCardiac Nuclear ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingPharmacologic Stress ImagingAdenosine Stress ImagingAntagonist ActivityCaffeine IngestionCardiac Ischemia ImagingCardiac Myocardial Perfusion ImagingCardiac Stress TestingMyocardial Perfusion ReservePerfusion Index
BACKGROUND: Adenosine is used in stress perfusion cardiac imaging to reveal myocardial ischemia by its vasodilator effects. Caffeine is a competitive antagonist of adenosine. However, previous studies reported inconsistent results about the influence of caffeine on adenosine's vasodilator effect. This study assessed the impact of caffeine on the myocardial perfusion reserve index (MPRI) using adenosine stress cardiovascular magnetic resonance imaging (CMR). Moreover, we sought to evaluate if the splenic switch-off sign might be indicative of prior caffeine consumption. METHODS: Semiquantitative perfusion analysis was performed in 25 patients who underwent: 1) caffeine-naïve adenosine stress CMR demonstrating myocardial ischemia and, 2) repeat adenosine stress CMR after intake of caffeine. MPRI (global; remote and ischemic segments), and splenic perfusion ratio (SPR) were assessed and compared between both exams. RESULTS: Global MPRI after caffeine was lower vs. caffeine-naïve conditions (1.09 ± 0.19 vs. 1.24 ± 0.19; p < 0.01). MPRI in remote myocardium decreased by caffeine (1.24 ± 0.19 vs. 1.49 ± 0.19; p < 0.001) whereas MPRI in ischemic segments (0.89 ± 0.18 vs. 0.95 ± 0.23; p = 0.23) was similar, resulting in a lower MPRI ratio (=remote/ischemic segments) after caffeine consumption vs. caffeine-naïve conditions (1.41 ± 0.19 vs. 1.64 ± 0.35, p = 0.01). The SPR was unaffected by caffeine (SPR 0.38 ± 0.19 vs. 0.38 ± 0.18; p = 0.92). CONCLUSION: Caffeine consumption prior to adenosine stress CMR results in a lower global MPRI, which is driven by the decreased MPRI in remote myocardium and underlines the need of abstinence from caffeine. The splenic switch-off sign is not affected by prior caffeine intake.
31
Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery Disease
Eike Nagel, Christoph Klein, Ingo Paetsch et al. · Circulation · 2003 · 624 citations · Full text
Medicine, Cardiology, Radiology +17
Igor Klem, John F. Heitner, Dipan J. Shah et al. · Journal of the American College of Cardiology · 2006 · 418 citations
Medicine, Cardiology, Radiology +16
Timothy Lockie, Masaki Ishida, Divaka Perera et al. · Journal of the American College of Cardiology · 2010 · 213 citations · Full text
Medicine, Cardiology, Radiology +14