Energies · 2019 · 18 citations · 12 references
Natural SciencesElectrical EngineeringPhysicsComputational ElectromagneticsElectromagneticsElectromagnetismElectromagnetic MethodsMagnetic CharacterizationMagnetic Circuit AnalysisMagnetic FieldsMagnetic Materials SimulationNonlinear Finite Element AnalysisHysteresisHysteresis BehaviorHysteresis Loop SimulationMagnetic FluxMagnetic Flux DensityMagnetic Hysteresis AnalysisMagnetic Hysteresis ModelingMagnetic Shielding
To enable the realization of ultra-low magnetic fields for scientific and technological research, magnetic shielding is required to create a space with low residual magnetic field and high shielding factors. The shielding factors of magnetic shields are due to nonlinear material properties, the geometry and structure of the shields, and the external magnetic fields. Magnetic shielding is used in environments full of random realistic disturbances, resulting in an arbitrary and random external magnetic field, and in this case, the shielding effect is hard to define simply by the shielding factors. A new method to simulate and predict a dynamic internal space magnetic field wave is proposed based on the Finite Element method (FEM) combined with the Jiles-Atherton (JA) model. By simulating the hysteresis behavior of the magnetic shields and establishing a dynamic model, the new method can simulate dynamic magnetic field changes inside magnetic shields as long as the external disturbances are known. The shielding factors under an AC external field with a sine wave and certain frequencies are calculated to validate the feasibility of the new method. A real-time wave of internal magnetic flux density under an AC triangular wave external field is simulated directly with the new method versus a method that splits the triangular wave into several sine waves by a Fourier transform, divides the shielding factors, and then adds the quotients together. Moreover, real-time internal waves under some arbitrary fields are measured. Experimental internal magnetic flux density waves of a 4-layer magnetically shielded room (MSR) at the Harbin Institute of Technology (HIT) fit the simulated results well, taking experimental errors into account.
12
Theory of ferromagnetic hysteresis
David Jiles, D.L. Atherton · Journal of Magnetism and Magnetic Materials · 1986 · 2.2K citations
Theory of ferromagnetic hysteresis (invited)
David Jiles, D.L. Atherton · Journal of Applied Physics · 1984 · 672 citations
Design, construction, and performance of a large-volume magnetic shield
Väinö Kelhä, J. Pukki, R. Peltonen et al. · IEEE Transactions on Magnetics · 1982 · 210 citations