Journal of Glaucoma · 2019 · 24 citations · 25 references
MedicineOphthalmologyVision ScienceClinical OptometryOcular DiseaseOphthalmic SurgeryCorneal BiomechanicsEye Movement AnalysisGlaucomaIntraocular Pressure MeasurementOcular BiometryOcular MotilityAxial Length CorrelationBiomechanical TestingCentral Corneal Thickness MeasurementCorneal Biomechanical EffectsCorneal Thickness AssessmentEye Movement BiomechanicsIntraocular Pressure Effects On Corneal MechanicsPrimary Angle-closure Glaucoma
PURPOSE: To evaluate the relationship between biomechanical parameters measured with a dynamic Scheimpflug analyzer and glaucoma. PATIENTS AND METHODS: Cross-sectional observational data of 47 eyes of 47 consecutive subjects with medically controlled primary open-angle glaucoma and 75 eyes of 75 healthy subjects examined with a dynamic Scheimpflug analyzer (Corvis ST) were retrospectively investigated. Eight biomechanical parameters were compared between eyes with and without glaucoma using multivariable models adjusting for intraocular pressure (IOP), central corneal thickness, age, and axial length. RESULTS: In multivariable models, glaucoma was negatively correlated with A1 time (P<0.001, coefficient=-0.5535), A2 time (P=0.008, coefficient=-0.1509), radius (P=0.011, coefficient=-0.4034), and whole eye movement (P<0.001, coefficient=-0.0622). Negative correlation between glaucoma and 3 parameters (A1 time, A2 time, and radius) consistently indicate larger deformability of the cornea and negative correlation between glaucoma and whole eye movement indicate smaller eye movement, in glaucoma eyes. There were significant correlations of many biomechanical parameters with other baseline factors (8 parameters with IOP, 2 with central corneal thickness, 4 with age, and 7 with axial length). CONCLUSIONS: Eyes with medically controlled glaucoma were more deformable than healthy eyes, which may increase the risk of optic nerve damage through an underestimation of IOP and biomechanical vulnerability of the globe. Many parameters showed a significant correlation with baseline factors, suggesting the importance of adjustment for these confounding factors when evaluating the correlation between biomechanical parameters and ocular diseases. These results suggest the relevance of measuring biomechanical properties of glaucoma eyes for accurate IOP measurement and risk assessment.
25
Daniel D. Murray, Kazuo Suzuki, Matthew Law et al. · PLoS ONE · 2015 · 2.7K citations · Full text
The Ocular Hypertension Treatment Study
Mae O. Gordon · Archives of Ophthalmology · 2002 · 2.6K citations
APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESS
Niels Ehlers, Thorkild Bramsen, STEFFEN SPERLING · Acta Ophthalmologica · 1975 · 942 citations
Medicine, Ophthalmology, Optometry +14