Diagnostic and Interventional Radiology · 2019 · 27 citations · 50 references
MedicineOncologyRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingComputed TomographyMedical ImagingPulmonary Embolism ImagingPulmonary ImagingThoracic Oncology ImagingVascular ImagingComputed Tomography AngiographyContrast Dose OptimizationContrast EnhancementContrast Enhancement PatternsContrast-enhanced Imaging Dose OptimizationImage Acquisition QualityPulmonary Artery ImagingSignal-to-noise Ratio Enhancement
PURPOSE: We aimed to determine if the image quality and vascular enhancement are preserved in computed tomography pulmonary angiography (CTPA) studies performed with ultra-low contrast and optimized radiation dose using high-pitch helical mode of a second generation dual source scanner. METHODS: We retrospectively evaluated oncology patients who had CTPA on a 128-slice dual-source scanner, with a high-pitch helical mode (3.0), following injection of 30 mL of Ioversal at 4 mL/s with body mass index (BMI) dependent tube potential (80-120 kVp) and current (130-150 mAs). Attenuation, noise, and signal-to-noise ratio (SNR) were measured in multiple pulmonary arteries. Three independent readers graded the images on a 5-point Likert scale for central vascular enhancement (CVE), peripheral vascular enhancement (PVE), and overall quality. RESULTS: There were 50 males and 101 females in our study. BMI ranged from 13 to 38 kg/m2 (22.8±4.4 kg/m2). Pulmonary embolism was present in 29 patients (18.9%). Contrast enhancement and SNR were excellent in all the pulmonary arteries (395.3±131.1 and 18.3±5.7, respectively). Image quality was considered excellent by all the readers, with average reader scores near the highest possible score of 5.0 (CVE, 4.83±0.48; PVE, 4.68±0.65; noise/quality, 4.78±0.47). The average radiation dose length product (DLP) was 161±60 mGy.cm. CONCLUSION: Using a helical high-pitch acquisition technique, CTPA images of excellent diagnostic quality, including visualization of peripheral segmental/sub-segmental branches can be obtained using an ultra-low dose of iodinated contrast and low radiation dose.
50
An Analysis of Variance Test for Normality (Complete Samples)
Samuel S. Shapiro, M. B. Wilk · Biometrika · 1965 · 5.9K citations
Risk Factors for Deep Vein Thrombosis and Pulmonary Embolism
John A. Heit, Marc D. Silverstein, David N. Mohr et al. · Archives of Internal Medicine · 2000 · 2.2K citations
Medicine, Hematology, Surgery +13
Multidetector Computed Tomography for Acute Pulmonary Embolism
Paul D. Stein, Sarah Fowler, Lawrence R. Goodman et al. · New England Journal of Medicine · 2006 · 1.6K citations · Full text