MedicineRadiation OncologyRadiation DosimetryRadiation ProtectionTreatment PlanningDose Uncertainty AnalysisExternal Beam DosimetryRadiation Dose MeasurementRadiation TherapyRadiation Treatment PlanningTreatment Planning Dose CalculationPlan Quality MetricsTreatment AccuracyTreatment Complexity MetricsTreatment Delivery AccuracyTreatment Planning DosimetryVolumetric Modulated Arc Therapy Dose CalculationVolumetric Modulated Arc Therapy DosimetryVolumetric Modulated Arc Therapy Planning
Abstract Purpose We evaluated the performance of various modulation indices ( MI ) for volumetric modulated arc therapy ( VMAT ) to predict plan delivery accuracy. Methods The specific indices evaluated were MI quantifying the mechanical uncertainty ( MI t ), MI quantifying the mechanical and dose calculation uncertainties ( MI c ), MI for station parameter optimized radiation therapy ( MI SPORT ), modulation complexity score for VMAT ( MCS v ), leaf travel modulation complexity score ( LTMCS ), plan averaged beam area ( PA ), plan averaged beam irregularity ( PI ), plan averaged beam modulation ( PM ), and plan normalized monitor unit ( PMU ) to predict VMAT delivery accuracy. By utilizing 240 VMAT plans generated with the Trilogy and TrueBeam ST x, Spearman's rank correlation coefficients ( r ) were calculated between the MI s and measures of conventional methods. Results For the Trilogy system, MI c showed the highest r values with gamma passing rates ( GPR s) ( r = −0.624 with P < 0.001 for Map CHECK 2 and r = −0.655 with P < 0.001 for Arc CHECK ). For TrueBeam ST x, MI c also showed the highest r values with GPR s ( r = −0.625 with P < 0.001 for the Map CHECK 2 and r = −0.561 with P < 0.001 for the Arc CHECK ). The MI t and MI c showed the highest r values to the MLC position errors for the Trilogy and TrueBeam ST x systems ( r = 0.770 with P < 0.001 and r = 0.712 with P < 0.001, respectively). The PA showed the highest percent of r values ( P < 0.05) to differences in the dose‐volume parameters between original VMAT plans and actual deliveries for the Trilogy systems (30.9%). Both the MI t and MI c showed the highest percent of r values ( P < 0.05) to differences in the dose‐volume parameters between original VMAT plans and actual deliveries for the TrueBeam ST x systems (31.8%). Conclusion To comprehensively review the results, the MI c showed the best performance to predict the VMAT delivery accuracy.
23
A technique for the quantitative evaluation of dose distributions
Daniel A. Low, William B. Harms, Sasa Mutic et al. · Medical Physics · 1998 · 2.9K citations · Full text
Volumetric modulated arc therapy: IMRT in a single gantry arc
Karl F. Otto · Medical Physics · 2007 · 1.9K citations · Full text
Medicine, Radiation Oncology, Clinical Radiation Oncology +16
Gary A. Ezzell, James M. Galvin, Daniel A. Low et al. · Medical Physics · 2003 · 877 citations · Full text