M. Hirsch, U. Höfel, Johan W. Oosterbeek, N. Chaudhary, J. Geiger, Hans‐Jürgen Hartfuß, W. Kasparek, N. B. Marushchenko, B. Ph. van Milligen, B. Plaum,

EPJ Web of Conferences · 2019 · 39 citations · 11 references

DOIFull text

Open access

Concepts

Abstract

The ECE diagnostic at W7-X in its standard mode of operation measures in X2 mode polarization with a 32 channel radiometer in the frequency band around 140 GHz for central magnetic field 2.5T. The radiometer is calibrated by a noise source and the overall system absolutely calibrated by means of a hot-cold source placed outside the torus in front of a Gaussian telescope optics with identical geometry and transmission line as it is installed for the measurements in the plasma vessel. The system is supplemented with a 16 channel zoom device with 4 GHz span for higher frequency resolution at a suitable radial range and a Michelson interferometer for the characterization of higher harmonics sharing the same line of sight.