IEEJ Journal of Industry Applications · 2019 · 12 citations · 14 references
EngineeringElectrical EngineeringElectric MachinesMotor ControlPower ElectronicsAc-dc ConvertersDc-ac InvertersElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsBack Electromotive ForceElectric Motor ControlElectrolytic CapacitorsHarmonic MitigationHarmonic ReductionHarmonicsInitial Condition ResponseLoss Reduction Techniques
To reduce the cost of an AC-DC-AC system, a single-phase-to-three-phase electrolytic capacitor-less inverter has been proposed. In particular, to satisfy the requirements of a harmonic source current, it is necessary to control the source current under sinusoidal waveform conditions. However, the DC-link voltage becomes an absolute value of the source voltage, and the output voltage is almost zero near the zero-crossing region of the source voltage. In the zero-output-voltage region, the motor current response deteriorates while controlling the sinusoidal source current. When the motor speed is high, the copper loss is always large because the motor current in the zero-output-voltage region depends on the back-electromotive force of the motor. To suppress the copper loss in the zero-output-voltage region, this paper proposes a copper-loss reduction control method that utilizes the initial-condition response of the motor current.
14