PubMed · 2018 · 16 citations · 27 references
EngineeringBioengineeringBiomedical EngineeringBiocompatibilityRegenerative MedicineTissue EngineeringBiomaterials For RegenerationBiomaterials For Tissue EngineeringCollagen-based BiomaterialsRegenerative ScaffoldsSkin RegenerationTissue RepairArtificial Skin SubstitutesCollagen BiomaterialsCollagen-based GraftsDermal RegenerationTissue Regeneration
OBJECTIVE: Graft rejection, with the possibility of a violent immune response, may be severe and life threatening. Our aim was to thoroughly investigate the biocompatibility and immunotoxicology of collagen-based dermal matrix (DM) before assessment in clinical trials. METHODS: DM was subcutaneously implanted in BALB/c mice in two doses to induce a potential immune response. The spleen and lymph nodes were assessed for shape, cell number, cell phenotype via flow cytometry, cell activation via CCK8 kit, Annexin V kit, and Ki67 immunostaining. Serum samples were used to measure antibody concentration by enzyme-linked immunosorbent assay. Local inflammation was analyzed by histology and immunohistochemistry staining. Data analysis was performed by one-way ANOVA and non-parametric tests. RESULTS: Our data illustrate that the spleen and lymph node sizes were similar between the negative control mice and mice implanted with DM. However, in the high-dose DM (DM-H) group, the total cell populations in the spleen and lymph nodes, T cells and B cells in the spleen had slight increases in prophase, and the low-dose DM (DM-L) group did not display gross abnormities. Moreover, DM-H initiated moderate cell activation and proliferation in the early phase post-immunization, whereas DM-L did not. Neither DM-H nor DM-L implantation noticeably increased IgM and IgG serum concentrations. Examination of the local cellular response revealed only benign cell infiltration and TNF-α expression in slides of DM in the early phase. CONCLUSION: Overall, DM-H may have induced a benign temporary acute immune response post-implantation, whereas DM-L had quite low immunogenicity. Thus, this DM can be regarded as a safe product.
27
Biocompatibility analysis of poly(glycerol sebacate) as a nerve guide material
Cathryn A. Sundback, J SHYU, Yadong Wang et al. · Biomaterials · 2005 · 440 citations
Gary A. Rosenberg, Lee Anna Cunningham, James A. Wallace et al. · Brain Research · 2001 · 389 citations
Medicine, Neurobiology, Neuroscience +14
Skin-on-a-chip model simulating inflammation, edema and drug-based treatment
Maierdanjiang Wufuer, GeonHui Lee, Woojune Hur et al. · Scientific Reports · 2016 · 340 citations · Full text