F1000Research · 2019 · 18 citations · 11 references
MedicineOncologySurgeryAnesthesiaSurgical OncologyVentilationHigh-frequency VentilationMechanical VentilationRespiratory ComplicationsRespiratory Effects Of AnesthesiaRespiratory MonitoringHigh-frequency Jet VentilationJet VentilationLactate ElevationLactate ProductionLiver Tumor AblationLung Function TestingRespiratory Gas ExchangeStereotactic Ablation
<ns4:p> <ns4:bold>Background:</ns4:bold> Stereotactic ablation of tumours in solid organs is a promising curative procedure in clinical oncology. The technique demands minimal target organ movements to optimise tumour destruction and prevent injury to surrounding tissues. High frequency jet ventilation (HFJV) is a novel option during these procedures, reducing the respiratory-associated movements of the liver. The effects of HFJV via endotracheal catheter on gas exchange during liver tumour ablation is not well studied. </ns4:p> <ns4:p> <ns4:bold>Methods:</ns4:bold> The aim of this explorative study was to assess lung function and the effects on blood gas and lactate during HFJV in patients undergoing stereotactic liver ablation. Blood gases were analysed in 25 patients scheduled for stereotactic liver ablation under general anaesthesia pre-induction, every 15 minutes during HFJV and following extubation in the recovery room. The HFJV was set at fixed settings. </ns4:p> <ns4:p> <ns4:bold>Results:</ns4:bold> None of the patients developed hypoxia or signs of increased lactate production but a great variation in PaO <ns4:sub>2</ns4:sub> /FiO <ns4:sub>2</ns4:sub> ratio was found; from 13.1 to 71.3. An increase in mean PaCO <ns4:sub>2</ns4:sub> was observed, from a baseline of 5.0 to a peak of 7.1 at 30 minutes (p <0.001) and a decrease was found in median pH, from a baseline of 7.44 to 7.31 at 15 minutes (p=0.03). We could not see any clear association between a decrease in PaO <ns4:sub>2</ns4:sub> /FiO <ns4:sub>2</ns4:sub> ratio and PaCO <ns4:sub>2</ns4:sub> elevation. </ns4:p> <ns4:p> <ns4:bold>Conclusions:</ns4:bold> HFJV during general anaesthesia in patients undergoing stereotactic liver ablation is feasible and it did not cause hypoxemia or signs of increased lactate production. A reversible mild to moderate impairment of gas exchange was found during HFJV. </ns4:p>
11
Lung Collapse and Gas Exchange during General Anesthesia
L. Tokics, Göran Hedenstierna, Åke Strandberg et al. · Anesthesiology · 1987 · 380 citations · Full text
Medicine, Anesthesiology, Radiology +13
Ida-Maria Gustafsson, Åse Lodenius, Jonas Tunelli et al. · British Journal of Anaesthesia · 2017 · 333 citations
Veterinary Medicine, Anesthesiology, Respiratory Therapy +13
A. Reber, G. Engberg, G. Wegenius et al. · Anaesthesia · 1996 · 102 citations · Full text