Physics in Medicine and Biology · 2019 · 16 citations · 14 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyHybrid ImagingComputed TomographyFluoroscopic ImagingHepatobiliary ImagingMedical ImagingNuclear Medicine ImagingTumor ImagingFluoroscopic GuidanceImage Acquisition QualityProcedural GuidanceReconstruction Quality AssessmentScanner OptimizationSignal-to-noise RatioSingle-photon DetectorsSingle-photon Emission Computed Tomography Detectors
Fluoroscopic procedures involving radionuclides would benefit from interventional nuclear imaging by obtaining real-time feedback on the activity distribution. We have previously proposed a dual-layer detector that offers such procedural guidance by simultaneous fluoroscopic and nuclear planar imaging. Acquisition of single photon computed tomography (SPECT) and cone beam computed tomography (CBCT) could provide additional information on the activity distribution. This study investigates the feasibility and the image quality of simultaneous SPECT/CBCT, by means of phantom experiments and simulations. Simulations were performed to study the obtained reconstruction quality for (i) clinical SPECT/CT, (ii) a dual-layer scanner configured with optimized hardware, and (iii) our (non-optimized) dual-layer prototype. Experiments on an image quality phantom and an anthropomorphic phantom (including extrahepatic depositions with volumes and activities close to the median values encountered in hepatic radioembolization) were performed with a clinical SPECT/CT scanner and with our dual-layer prototype. Nuclear images were visually and quantitatively evaluated by measuring the tumor/non-tumor (T/N) ratio and contrast-to-noise ratio (CNR). The simulations showed that the maximum obtained CNR was 38.8 ± 0.8 for the clinical scanner, 30.2 ± 0.9 for the optimized dual-layer scanner, and 20.8 ± 0.4 for the prototype scanner. T/N ratio showed a similar decline. The phantom experiments showed that performing simultaneous SPECT/CBCT is feasible. The CNR obtained from the SPECT reconstruction of largest sphere in the image quality phantom was 43.1 for the clinical scanner and 28.6 for the developed prototype scanner. The anthropomorphic phantom showed that the extrahepatic depositions were detected with both scanners. A dual-layer detector is able to simultaneously acquire SPECT and CBCT. Both CNR and T/N ratio are worse than that of a clinical system, but the phantom experiments showed that extrahepatic depositions with volumes and activities close to the median values encountered in hepatic radioembolization could be distinguished.
14
elastix: A Toolbox for Intensity-Based Medical Image Registration
Stefan Klein, Marius Staring, Keelin Murphy et al. · IEEE Transactions on Medical Imaging · 2009 · 4.4K citations
GATE: a simulation toolkit for PET and SPECT
S Jan, G. Santin, D. Strul et al. · Physics in Medicine and Biology · 2004 · 2.1K citations · Full text
4D XCAT phantom for multimodality imaging research
W. Paul Segars, Gregory M. Sturgeon, S. Mendonca et al. · Medical Physics · 2010 · 1.3K citations · Full text
TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
Ander Biguri, Manjit Dosanjh, S. Hancock et al. · Biomedical Physics & Engineering Express · 2016 · 352 citations · Full text