Journal of Computer Assisted Tomography · 2019 · 18 citations · 29 references
MedicineMaternal HealthObstetricsMaternal-fetal MedicineNeonatologyPrenatal DiagnosisFetal ImagingIntrauterine Growth RestrictionPlacental AssessmentPlacental ImagingPlacental PhysiologyPregnancy ImagingApparent Diffusion Coefficient AnalysisDiffusion Coefficient CalculationDiffusion Coefficient EstimationFetal Lung ImagingFetal MriIntrauterine Fetal Growth RestrictionIntrauterine Growth Restriction MonitoringPlacental Diffusion Imaging
PURPOSE: This study aimed to assess apparent diffusion coefficient (ADC) of the placenta and fetal organs in intrauterine growth restriction (IUGR). MATERIALS AND METHODS: A prospective study of 30 consecutive pregnant women (aged 21-38 years with mean age of 31.5 years and a mean gestational week of 35 ± 2.3) with IUGR and 15 age-matched pregnant women was conducted. All patients and controls underwent diffusion-weighted magnetic resonance imaging. The ADCs of the placenta and fetal brain, kidney, and lung were calculated and correlated with neonates needing intensive care unit (ICU) admission. RESULTS: There was a significant difference in ADC of the placenta and fetal brain, lung, and kidney (P = 0.001, 0.001, 0.04, and 0.04, respectively) between the patients and the controls. The cutoff ADCs of the placenta and fetal brain, lung, and kidney used to detect IUGR were 1.45, 1.15, 1.80, and 1.40 × 10 mm/s, respectively, with areas under the curve (AUCs) of 0.865, 0.858, 0.812, and 0.650, respectively, and accuracy values of 75%, 72.5%, 72.5%, and 70%, respectively. Combined ADC of the placenta and fetal organs used to detect IUGR revealed an AUC of 1.00 and an accuracy of 100%. There was a significant difference in ADC of the placenta and fetal brain, lung, and kidney between neonates needing admission and those not needing ICU admission (P = 0.001, 0.001, 0.002, and 0.002, respectively). The cutoff ADCs of the placenta and fetal brain, lung, and kidney used to define neonates needing ICU were 1.35, 1.25, 1.95, and 1.15 × 10 mm/s with AUCs of 0.955, 0.880, 0.884, and 0.793, respectively, and accuracy values of 86.7%, 46.7%, 76.7%, and 70%, respectively. Combined placental and fetal brain ADC used to define neonates needing ICU revealed an AUC of 0.968 and an accuracy of 93.3%. CONCLUSION: Combined ADC of the placenta and fetal organs can detect IUGR, and combined ADC of the placenta and fetal brain can define fetuses needing ICU.
29
Imaging Spectrum of CNS Vasculitis
Ahmed Abdel Khalek Abdel Razek, H. Álvarez, Stephen D. Bagg et al. · Radiographics · 2014 · 241 citations
Ali R. Sepahdari, Letterio S. Politi, Vinay K. Aakalu et al. · American Journal of Neuroradiology · 2013 · 150 citations · Full text
Diffusion-weighted MR Imaging of the Placenta in Fetuses with Placental Insufficiency
Harald Bonél, Bernhard Stolz, Lars Diedrichsen et al. · Radiology · 2010 · 112 citations
Medicine, Obstetrics, Radiology +17