Korean Journal of Ophthalmology · 2019 · 14 citations · 16 references
MedicineOphthalmologySurgeryAnterior SegmentMicrosurgeryOphthalmic SurgeryBiomedical Laser ApplicationsCorneal ImagingCorneal TomographyLaser In Situ KeratomileusisLaser SurgeryOptical Coherence TomographyAnterior Segment TomographyCorneal Optical Coherence TomographyFemtosecond Laser UseFlap CreationFlap Thickness SelectionIntraoperative Optical Coherence TomographyOptical Keratoplasty
PURPOSE: keratomileusis (LASIK) flap thickness predictability and morphology by femtosecond (FS) laser and microkeratome (MK) using anterior segment optical coherence tomography. METHODS: Fifty-two candidates for the LASIK procedure were stratified into two groups: FS laser-assisted (Allegretto FS-200) and MK flap creation (Moria 2). Flap thickness was determined at five points. The side-cut angle was measured in three directions at the margin interface. LASIK flap assessment was performed one month postoperatively by Spectralis anterior segment optical coherence tomography. RESULTS: Fifty-two patients (93 eyes) were recruited; 49 eyes were stratified to the FS group and 44 eyes to the MK group. The FS group had relatively even flap configurations, and the MK group had meniscus-shaped flaps. Mean differences between planned and actual flap thickness were 12.93 ± 8.89 and 19.91 ± 5.77 μm in the FS and MK groups, respectively. In thin flaps (100 to 110 μm), there was a significant disparity between the two groups (7.80 ± 4.71 and 19.44 ± 4.46 μm in the FS and MK groups, respectively). However, in thicker flaps (130 μm), comparable flap thickness disparity was achieved (18.54 ± 9.52 and 20.83 ± 5.99 μm in the FS and MK groups, respectively). Mean side-cut angle was 74.29 ± 5.79 degrees and 32.34 ± 4.94 degrees in the FS and MK groups, respectively. CONCLUSIONS: Comparable flap thickness predictability was achieved in thicker flaps (130 μm), while the FS laser technique yielded a more predictable result in thinner flaps (100 to 110 μm). Different flap morphology was observed in meniscus flaps in MK-LASIK and flap morphology in FS-LASIK.
16
NIH Image to ImageJ: 25 years of image analysis
Caroline A Schneider, Wayne Rasband, Kevin W. Eliceiri · Nature Methods · 2012 · 65.2K citations
Laser in situ keratomileusis for myopia and astigmatism: safety and efficacy
Alan Sugar, Christopher J. Rapuano, William W. Culbertson et al. · Ophthalmology · 2002 · 408 citations
Medicine, Ophthalmology, Surgery +12
Claudia M. Prospero Ponce, Karolinne Maia Rocha, Scott D. Smith et al. · Journal of Cataract & Refractive Surgery · 2009 · 155 citations
Medicine, Ophthalmology, Surgery +17
Photodisruption in the Human Cornea as a Function of Laser Pulse Width
Ron M. Kurtz, Xinbing Liu, Victor M. Elner et al. · Journal of Refractive Surgery · 1997 · 101 citations