PLoS ONE · 2019 · 17 citations · 44 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyProstheticsAortic Valve DiseaseCardiac Valve SurgeryHemodynamicsProsthetic MaterialsSurgical Valve ReplacementAortic Valve HemodynamicsFinite Element ModelingHeart Valve HemodynamicsHeart Valve ModelingIn-vitro CharacterizationLeaflet CoaptationValve MechanicsValve Prosthesis Design
The expanded polytetrafluoroethylene (ePTFE) heart valve can serve as a viable option for prosthetic aortic valve. In this study, an ePTFE bi-leaflet valve design for aortic valve replacement (AVR) is presented, and the performance of the proposed valve was assessed numerically and experimentally. The valve was designed using CAE software. The dynamic behavior of the newly designed bi-leaflet valve under time-varying physiological pressure loading was first investigated by using commercial finite element code. Then, in-vitro tests were performed to validate the simulation and to assess the hemodynamic performance of the proposed design. A tri-leaflet ePTFE valve was tested in-vitro under the same conditions as a reference. The maximum leaflet coaptation area of the bi-leaflet valve during diastole was 216.3 mm2. When fully closed, no leakage gap was observed and the free edges of the molded valve formed S-shaped lines. The maximum Von Mises stress during a full cardiac cycle was 4.20 MPa. The dynamic performance of the bi-leaflet valve was validated by the in-vitro test under physiological aortic pressure pulse. The effective orifice area (EOA), mean pressure gradient, regurgitant volume, leakage volume and energy loss of the proposed valve were 3.14 cm2, 8.74 mmHg, 5.93 ml/beat, 1.55 ml/beat and 98.99 mJ, respectively. This study reports a novel bi-leaflet valve design for AVR. The performance of the proposed valve was numerically and experimentally assessed. Compared with the reference valve, the proposed design exhibited better structural and hemodynamic performances, which improved valve competency. Moreover, the performance of the bi-leaflet design is comparable to commercialized valves available on the market. The results of the present study provide a viable option for the future clinical applications.
44
REPLACEMENT OF AORTIC AND MITRAL VALVES WITH A PULMONARY AUTOGRAFT
D. N. Ross · The Lancet · 1967 · 962 citations
Medicine, Cardiology, Surgery +10
José F. Rodríguez‐Palomares, Lydia Dux‐Santoy, Andrea Guala et al. · Journal of Cardiovascular Magnetic Resonance · 2018 · 229 citations · Full text