Neurophotonics · 2018 · 15 citations · 29 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingBiomedical OpticsDiagnostic ImagingBrain ImagingFiber-optic Medical DevicesFunctional NeuroimagingMagnetic Resonance ImagingMedical ImagingOptical TomographyDiffuse Optical ImagingDiffuse Optical TomographyField Of ViewField Of View ReductionFunctional Magnetic Resonance ImagingHigh Dynamic Range (Hdr) ImagingIn-pixel BinningSignal-to-noise Ratio
Though optical imaging of human brain function is gaining momentum, widespread adoption is restricted in part by a tradeoff among cap wearability, field of view, and resolution. To increase coverage while maintaining functional magnetic resonance imaging (fMRI)-comparable image quality, optical systems require more fibers. However, these modifications drastically reduce the wearability of the imaging cap. The primary obstacle to optimizing wearability is cap weight, which is largely determined by fiber diameter. Smaller fibers collect less light and lead to challenges in obtaining adequate signal-to-noise ratio. Here, we report on a design that leverages the exquisite sensitivity of scientific CMOS cameras to use fibers with ∼30 × smaller cross-sectional area than current high-density diffuse optical tomography (HD-DOT) systems. This superpixel sCMOS DOT (SP-DOT) system uses 200-μm-diameter fibers that facilitate a lightweight, wearable cap. We developed a superpixel algorithm with pixel binning and electronic noise subtraction to provide high dynamic range (>105), high frame rate (>6 Hz), and a low effective detectivity threshold (∼200 fW / Hz1/2-mm2), each comparable with previous HD-DOT systems. To assess system performance, we present retinotopic mapping of the visual cortex (n = 5 subjects). SP-DOT offers a practical solution to providing a wearable, large field-of-view, and high-resolution optical neuroimaging system.
29
John C. Mazziotta, Arthur W. Toga, Alan C. Evans et al. · Philosophical Transactions of the Royal Society B Biological Sciences · 2001 · 2.4K citations · Full text
Medicine, Neurobiology, Neuroscience +15
Susan Wray, Mark Cope, David T. Delpy et al. · Biochimica et Biophysica Acta (BBA) - Bioenergetics · 1988 · 914 citations
Bolometers for infrared and millimeter waves
P. L. Richards · Journal of Applied Physics · 1994 · 883 citations
Fluorescence molecular tomography resolves protease activity in vivo
Vasilis Ntziachristos, Ching‐Hsuan Tung, Christoph Bremer et al. · Nature Medicine · 2002 · 825 citations