American Journal of Infection Control · 2019 · 42 citations · 43 references
Public HealthMicrobiologySurgeryEnvironmental HealthInfection PreventionMedical MicrobiologyEnvironmental CleaningEnvironmental DisinfectionMicrobial ContaminationSurgical Infection ManagementSurgical Site InfectionCleaningColony-forming Unit AssaysColony-forming Unit EnumerationMicrobial Contamination ControlMicrobial Contamination RiskOperating Room Contamination ControlOperating Room Infection PreventionSurface Contamination
BackgroundA growing body of research has demonstrated that manual cleaning and disinfection of the operating room (OR) is suboptimal. Residual environmental contamination may pose an infection risk to the surgical wound. This study evaluates the impact of a visible-light continuous environmental disinfection (CED) system on microbial surface contamination and surgical site infections (SSI) in an OR.MethodsSamples from 25 surfaces within 2 contiguous ORs sharing an air supply were obtained after manual cleaning on multiple days before and after a visible-light CED system installation in 1 of the ORs. Samples were incubated and enumerated as total colony-forming units. SSIs in both ORs, and a distant OR, were tracked for 1 year prior to and 1 year after the visible-light CED system installation.ResultsThere was an 81% (P = .017) and 49% (P = .015) reduction in total colony-forming units after the visible-light CED system installation in the OR in which the system was installed, and in the contiguous OR, respectively. In the OR with the visible-light CED system, SSIs decreased from 1.4% in the year prior to installation to 0.4% following installation (P = .029).ConclusionsA visible-light CED system, used in conjunction with manual cleaning, resulted in significant reductions in both microbial surface contamination and SSIs in the OR. A growing body of research has demonstrated that manual cleaning and disinfection of the operating room (OR) is suboptimal. Residual environmental contamination may pose an infection risk to the surgical wound. This study evaluates the impact of a visible-light continuous environmental disinfection (CED) system on microbial surface contamination and surgical site infections (SSI) in an OR. Samples from 25 surfaces within 2 contiguous ORs sharing an air supply were obtained after manual cleaning on multiple days before and after a visible-light CED system installation in 1 of the ORs. Samples were incubated and enumerated as total colony-forming units. SSIs in both ORs, and a distant OR, were tracked for 1 year prior to and 1 year after the visible-light CED system installation. There was an 81% (P = .017) and 49% (P = .015) reduction in total colony-forming units after the visible-light CED system installation in the OR in which the system was installed, and in the contiguous OR, respectively. In the OR with the visible-light CED system, SSIs decreased from 1.4% in the year prior to installation to 0.4% following installation (P = .029). A visible-light CED system, used in conjunction with manual cleaning, resulted in significant reductions in both microbial surface contamination and SSIs in the OR.
43
Economic Burden of Periprosthetic Joint Infection in the United States
Steven M. Kurtz, Edmund Lau, Heather Watson et al. · The Journal of Arthroplasty · 2012 · 1.7K citations
Annette Erichsen Andersson, Ingrid Bergh, Jón Karlsson et al. · American Journal of Infection Control · 2012 · 263 citations