Journal of Thrombosis and Haemostasis · 2019 · 43 citations · 30 references
MedicineHematologyHemostasisResuscitationTransfusion MedicineBlood Transfusion ManagementPlasma TransfusionPlatelet PhysiologyPlatelet TransfusionThrombosisTrauma ResuscitationBlood Transfusion TherapyPlatelet Transfusion In TraumaPlatelet Transfusion TherapyTranexamic Acid AdministrationTransfusion In CoagulopathyTransfusion In Trauma CareTrauma CoagulopathyTrauma Resuscitation With Plasma
Essentials•The response of thromboelastometry (ROTEM) parameters to therapy is unknown.•We prospectively recruited hemorrhaging trauma patients in six level‐1 trauma centres in Europe.•Blood products and pro‐coagulants prevent further derangement of ROTEM results.•ROTEM algorithms can be used to treat and monitor trauma induced coagulopathy.SummaryBackgroundRotational thromboelastometry (ROTEM) can detect trauma‐induced coagulopathy (TIC) and is used in transfusion algorithms. The response of ROTEM to transfusion therapy is unknown.ObjectivesTo determine the response of ROTEM profiles to therapy in bleeding trauma patients.Patients/MethodsA prospective multicenter study in bleeding trauma patients (receiving ≥ 4 red blood cell [RBC] units) was performed. Blood was drawn in the emergency department, after administration of 4, 8 and 12 RBC units and 24 h post‐injury. The response of ROTEM to plasma, platelets (PLTs), tranexamic acid (TXA) and fibrinogen products was evaluated in the whole cohort as well as in the subgroup of patients with ROTEM values indicative of TIC.ResultsThree hundred and nine bleeding and shocked patients were included. A mean dose of 3.8 g of fibrinogen increased FIBTEM CA5 by 5.2 mm (IQR: 4.1–6.3 mm). TXA administration decreased lysis by 5.4% (4.3–6.5%). PLT transfusion prevented further derangement of parameters of clot formation. The effect of PLTs on EXTEM ca5 values was more pronounced in patients with a ROTEM value indicative of TIC than in the whole cohort. Plasma transfusion decreased EXTEM clotting time by 3.1 s (− 10 s to 3.9 s) in the whole cohort and by 10.6 s (− 45 s to 24 s) in the subgroup of patients with a ROTEM value indicative of TIC.ConclusionThe effects of therapy on ROTEM values were small, but prevented further derangement of test results. In patients with ROTEM values indicative of TIC, the efficacy of PLTs and plasma in correcting deranged ROTEM parameters is possibly more robust. Essentials•The response of thromboelastometry (ROTEM) parameters to therapy is unknown.•We prospectively recruited hemorrhaging trauma patients in six level‐1 trauma centres in Europe.•Blood products and pro‐coagulants prevent further derangement of ROTEM results.•ROTEM algorithms can be used to treat and monitor trauma induced coagulopathy. •The response of thromboelastometry (ROTEM) parameters to therapy is unknown.•We prospectively recruited hemorrhaging trauma patients in six level‐1 trauma centres in Europe.•Blood products and pro‐coagulants prevent further derangement of ROTEM results.•ROTEM algorithms can be used to treat and monitor trauma induced coagulopathy. Background Rotational thromboelastometry (ROTEM) can detect trauma‐induced coagulopathy (TIC) and is used in transfusion algorithms. The response of ROTEM to transfusion therapy is unknown. To determine the response of ROTEM profiles to therapy in bleeding trauma patients. A prospective multicenter study in bleeding trauma patients (receiving ≥ 4 red blood cell [RBC] units) was performed. Blood was drawn in the emergency department, after administration of 4, 8 and 12 RBC units and 24 h post‐injury. The response of ROTEM to plasma, platelets (PLTs), tranexamic acid (TXA) and fibrinogen products was evaluated in the whole cohort as well as in the subgroup of patients with ROTEM values indicative of TIC. Three hundred and nine bleeding and shocked patients were included. A mean dose of 3.8 g of fibrinogen increased FIBTEM CA5 by 5.2 mm (IQR: 4.1–6.3 mm). TXA administration decreased lysis by 5.4% (4.3–6.5%). PLT transfusion prevented further derangement of parameters of clot formation. The effect of PLTs on EXTEM ca5 values was more pronounced in patients with a ROTEM value indicative of TIC than in the whole cohort. Plasma transfusion decreased EXTEM clotting time by 3.1 s (− 10 s to 3.9 s) in the whole cohort and by 10.6 s (− 45 s to 24 s) in the subgroup of patients with a ROTEM value indicative of TIC. The effects of therapy on ROTEM values were small, but prevented further derangement of test results. In patients with ROTEM values indicative of TIC, the efficacy of PLTs and plasma in correcting deranged ROTEM parameters is possibly more robust.
30
Karim Brohi, Jasmin Singh, Mischa Heron et al. · The Journal of Trauma: Injury, Infection, and Critical Care · 2003 · 1.7K citations
Early Coagulopathy Predicts Mortality in Trauma
Jana MacLeod, Mauricio Lynn, Mark McKenney et al. · The Journal of Trauma: Injury, Infection, and Critical Care · 2003 · 1.2K citations
The Prospective, Observational, Multicenter, Major Trauma Transfusion (PROMMTT) Study
John B. Holcomb, Deborah J. del Junco, Erin E. Fox et al. · JAMA Surgery · 2012 · 1.1K citations · Full text
Goal-directed Hemostatic Resuscitation of Trauma-induced Coagulopathy
Eduardo González, Ernest E. Moore, Hunter B. Moore et al. · Annals of Surgery · 2015 · 632 citations · Full text
Medicine, Hematology, Hemostasis +16