Journal of Dairy Science · 2019 · 29 citations · 39 references
AgricultureInfectious DiseasesVeterinary MicrobiologyDairy MicrobiologyDiagnostic MicrobiologyMilk QualityMilk ContaminationMilk MicrobiologyNucleic Acid Amplification TestingPolymerase Chain ReactionIsothermal AmplificationLoop-mediated Isothermal AmplificationMycobacterium Bovis DetectionMycoplasma In MilkQuantitative Polymerase Chain ReactionQuantitative Polymerase Chain Reaction AssaysRapid Detection Assays
Bovine mastitis is an economic burden for dairies worldwide. Mycoplasma species, and especially Mycoplasma bovis, are among the most important causative agents, and rapid, precise, and low-cost methods for Mycoplasma detection are urgently needed. For this purpose, loop-mediated isothermal amplification (LAMP) and quantitative PCR (qPCR) assays were developed and compared. The LAMP assay was designed and primer concentrations optimized to M. bovis oppD, encoding oligopeptide permease D. For qPCR, a Taqman assay (Applied Biosystems, Carlsbad, CA) targeting M. bovis gltX, encoding glutamate transfer RNA ligase, was optimized for primer concentration, annealing temperature, and DNA polymerase. Both assays were similarly sensitive, with a detection limit of approximately 10 4 to 10 5 M. bovis cells/mL. Both assays were also successful in confirming M. bovis identity in laboratory culture suspensions and in bovine milk. The LAMP and qPCR assays combined with the MoBio DNA extraction kit (MoBio Laboratories Inc., Carlsbad, CA) resulted in the correct detection of 13 out of 13 M. bovis isolates and 14 out of 16 M. bovis-positive milk samples collected from commercial dairies in California. When combined with the PrepMan Ultra reagent (Applied Biosystems), the qPCR assay resulted in confirming 21 out of 21 M. bovis-positive milk samples. Comparison of the assays to milk containing either Mycoplasma arginini, Mycoplasma bovigenitalium, Mycoplasma californicum, M. alkalescens, or Acholeplasma laidlawii or milk lacking any detectable Mycoplasma species or relatives resulted in 3 out of 17 (LAMP with MoBio), 1 out of 17 (qPCR with MoBio), and 2 out of 36 (qPCR with PrepMan Ultra) false positives. Overall, the qPCR assay was more robust than LAMP and could be used on DNA recovered from milk prepared with the PrepMan Ultra reagent, a method that does not include a DNA purification step. The use of this qPCR method enables M. bovis detection in bovine milk in 40 to 55 min, and therefore provides new opportunities to accelerate and simplify M. bovis detection in unpasteurized milk to reduce the incidence of M. bovis mastitis outbreaks.
39
Julie Thompson, Desmond G. Higgins, Toby J. Gibson · Nucleic Acids Research · 1994 · 64.9K citations · Full text
Primer3—new capabilities and interfaces
Andreas Untergasser, Ioana Cutcutache, Triinu Kõressaar et al. · Nucleic Acids Research · 2012 · 9.8K citations · Full text
Loop-mediated isothermal amplification of DNA
Tsugunori Notomi · Nucleic Acids Research · 2000 · 8.8K citations · Full text
David Lane · Medical Entomology and Zoology · 1991 · 8K citations
Primer-BLAST: A tool to design target-specific primers for polymerase chain reaction
Jian Ye, George Coulouris, Irena Zaretskaya et al. · BMC Bioinformatics · 2012 · 6.2K citations · Full text