Separation of eight bedaquiline analogue diastereomers by HPLC on an immobilized polysaccharide‐based chiral stationary phase

Shenmeng Jiang, Chengjun Wu, Jia Yu, Tiemin Sun, Xingjie Guo

Chirality · 2018 · 13 citations · 17 references

Concepts

Abstract

The high-performance liquid chromatography (HPLC) is a powerful method in the area of stereoisomer separation. In this study, separation of eight bedaquiline analogue diastereomers (compounds 1-8) was first examined on a cellulose tris-(3,5-dichlorophenylcarbamate) chiral stationary phase, ie, Chiralpak IC in the normal phase mode. The influences of organic modifier types, alcohol content, and column temperature on diastereoseparation were evaluated. Under the optimum chromatographic conditions, all the analyte stereoisomers were successfully separated. The experimental results revealed the great influence of analytes' structures on the diastereoseparation with Chiralpak IC. In addition, thermodynamic parameters were calculated by Van't Hoff plots, and correlative chiral recognition mechanisms were discussed further.

References