Remote Sensing Letters · 2018 · 54 citations · 21 references
ComputingEarth SciencesGeoinformaticsComputer VisionGeomorphologyRemote SensingCurvature AnalysisDigital Elevation ModelsDigital Surface ModelsPhotogrammetric Elevation ModelingPhotogrammetrySlope AnalysisCurvature Error AnalysisCurvature Extraction From Digital Elevation ModelsDigital Elevation Model GenerationDigital Surface Model GenerationGeomorphological AnalysisMulti-view StereoMulti-view Stereo ReconstructionRandom Elements
PhotoScan builds digital surface models from UAV imagery using Structure‑from‑Motion and Multi‑View Stereo, but its internally random algorithms can introduce accuracy variations. The study aimed to quantify how much variation arises from ten identical runs of PhotoScan on rock‑glacier UAV imagery. The authors performed ten runs, measured per‑cell standard deviations in DSMs and curvature, and tested that medium‑quality runs with additional oblique views and at least five overlapping images reduce variability. Steep slopes exhibited up to 10 cm DSM variation yet remained within the 10 cm accuracy threshold for 88–96 % of the area, while model edges varied 0.10–3 m due to fewer overlaps, indicating that centimetre‑scale geomorphological studies must account for such uncertainties in complex relief.
In geomorphology, PhotoScan is a software that is used to produce Digital Surface Models (DSMs). It constructs 3D environments from 2D imagery (often taken by Unmanned Aerial Vehicles (UAV)) based on Structure-from-Motion (SfM) and Multi-View Stereo (MVS) principles. However, unpublished computer-vision algorithms used, contain random elements which can affect the accuracy of the outputs. For this letter, ten model runs with identical inputs were performed on UAV imagery of a rock glacier to analyse the magnitude of the variation between the different model outputs. This variation was quantified calculating the standard deviation of each cell value in the respective DSMs and derivatives (curvature). Places with steep slope gradients have considerably more DSM variation (up to 10 cm) but stay within the range of the model's accuracy (10 vertical cm) for 88 – 96% of the area. The edges of the model also show a larger variability (0.10 – 3 m), related to a lower number of overlapping images. These results should be accounted for when performing a geomorphological research at centimetre scale using PhotoScan, especially in areas with a complex relief. Using medium-quality runs, additional oblique viewpoints and respecting a minimum of five overlapping images can minimize the software's variations.
21