IEEE Transactions on Biomedical Engineering · 2018 · 39 citations · 18 references
EngineeringBioengineeringBiomedical EngineeringBiomedical Signal ProcessingBiosensorsSensorsBiomedical InstrumentationBiomedical SensorsOptical BiosensingOptical BiosensorsWearable BiosensorsWearable Health TechnologiesElectrophysiological MeasurementElectrophysiological RecordingsMotion Artifact MitigationMotion ArtifactsPhotoplethysmographyPhysiological MonitoringPulse OximetryWearable Devices
Advances in several engineering fields have led to a trend toward miniaturization and portability of wearable biosensing devices, which used to be confined to large tools and clinical settings. Various systems to continuously measure electrophysiological activity through electrical and optical methods are one category of such devices. Being wearable and intended for prolonged use, the amount of noise introduced on sensors by movement remains a challenge and requires further optimization. User movement causes motion artifacts that alter the overall quality of the signals obtained, hence corrupting the resulting measurements. This paper introduces a fully wearable optical biosensing system to continuously measure pulse oximetry and heart rate, utilizing a reflectance-based probe. Furthermore, a novel data-dependent motion artifact tailoring algorithm is implemented to eliminate noisy data due to the motion artifact and measure oxygenation level with high accuracy in real time. By taking advantages of current wireless transmission and signal processing technologies, the developed wearable photoplethysmography device successfully captures the measured signals and sends them wirelessly to a mobile device for signal processing in real time. After applying motion artifact tailoring, evaluating accuracy with a continuous clinical device, the blood oxygenation measurements obtained from our system yielded an accuracy of at least 98%, when compared to a range of 93.6%-96.7% observed before from the same initial data. Additionally, heart rate accuracy above 97% was achieved. Motion artifact tailoring and removal in real time, continuous systems will allow wearable devices to be truly wearable and a reliable electrophysiological monitoring and diagnostics tool for everyday use.
18
All-organic optoelectronic sensor for pulse oximetry
Claire M. Lochner, Yasser Khan, Adrien Pierre et al. · Nature Communications · 2014 · 715 citations · Full text
An Introduction to the Theory of Statistics
John Robinson, R. L. Plackett · Biometrics · 1974 · 563 citations
Accuracy of Heart Rate Watches: Implications for Weight Management
Matthew P. Wallen, Sjaan R. Gomersall, Shelley E. Keating et al. · PLoS ONE · 2016 · 359 citations · Full text