Translational Vision Science & Technology · 2018 · 24 citations · 48 references
MedicineOphthalmologyVision ScienceClinical Vision ScienceComputer VisionVisual PerceptionObstacle DetectionPeripheral VisionVision AssessmentVision ImpairmentVisual ImpairmentVisual Loss EvaluationDriving Simulator AssessmentPedestrian DetectionPeripheral Vision LossPeripheral Visual FieldPeripheral Visual Field LossPeripheral Visual Field TestingPrismsValidation Of Driving Simulator Models
PURPOSE: Peripheral field loss (PFL) due to retinitis pigmentosa, choroideremia, or glaucoma often results in a highly constricted residual central field, which makes it difficult for patients to avoid collision with approaching pedestrians. We developed a virtual environment to evaluate the ability of patients to detect pedestrians and judge potential collisions. We validated the system with both PFL patients and normally sighted subjects with simulated PFL. We also tested whether properly placed high-power prisms may improve pedestrian detection. METHODS: A virtual park-like open space was rendered using a driving simulator (configured for walking speeds), and pedestrians in testing scenarios appeared within and outside the residual central field. Nine normally sighted subjects and eight PFL patients performed the pedestrian detection and collision judgment tasks. The performance of the subjects with simulated PFL was further evaluated with field of view expanding prisms. RESULTS: The virtual system for testing pedestrian detection and collision judgment was validated. The performance of PFL patients and normally sighted subjects with simulated PFL were similar. The prisms for simulated PFL improved detection rates, reduced detection response times, and supported reasonable collision judgments in the prism-expanded field; detections and collision judgments in the residual central field were not influenced negatively by the prisms. CONCLUSIONS: The scenarios in a virtual environment are suitable for evaluating PFL and the impact of field of view expanding devices. TRANSLATIONAL RELEVANCE: This study validated an objective means to evaluate field expansion devices in reproducible near-real-life settings.
48
A Simple Sequentially Rejective Multiple Test Procedure
Sture Holm · Scandinavian Journal of Statistics · 1979 · 21.8K citations
On Methods in the Analysis of Profile Data
Samuel W. Greenhouse, Seymour Geisser · Psychometrika · 1959 · 5K citations
Optic flow is used to control human walking
William H. Warren, Bruce A. Kay, Wendy D. Zosh et al. · Nature Neuroscience · 2001 · 740 citations